Installation and setup
Learn how to install, connect, and optimize the projector display.
Site requirements
To safely install and operate the Christie Griffyn Series projectors, the installation location must meet
these minimum requirements.
Physical operating environment
•
Ambient temperature (operating) 5°C to 40°C (41°F to 104°F) up to 457.2 meters (1,500 feet)
•
Humidity (non-condensing) 10% to 80%
•
Operating altitude 0 to 3000 meters (0 to 9843 feet)
Non-operating environment (in shipping packaging)
•
Ambient temperature (operating) -25°C to 70°C (-13°F to 158°F)
•
Humidity (non-condensing) 10% to 80%
Product ventilation
Sufficient ventilation is required around the projector to regulate the temperature of the internal laser
module.
The installation site must provide an airflow 450 cubic feet per minute (CFM) at 1 to 1000 meters (3.3
to 3280.8 feet) elevation, and must accommodate a heat load of 3000 W.
For each additional 1000 meters (3,280.8 feet) above sea level, increase the airflow (CFM) value by
15%. If the increased airflow requirements cannot be met by the building’s HVAC system, the operating
temperature range is restricted to 5°C to 25°C (41°F to 77°F) at a maximum altitude of 3000 meters
(9,843 feet).
Power connection
Connect to AC power using the power cord provided with the projector.
This product is suitable for connection to an IT power distribution system.
Christie Griffyn Series Installation and Setup Guide
23
020-103314-08 Rev. 1 (06-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.