Adjusting the fold mirror
Fold mirror adjustment must be completed by trained personnel.
Notice. If not avoided, the following could result in property damage.
•
Misalignment of the fold mirror may cause permanent damage to the product.
1. Set the brightness to 30% or less before powering on the projector.
If the Brightness slider is greyed out, enable LiteLOC
™
.
2. From the Test Pattern menu, select the Integrator Rod test pattern.
3. Open the Service door on the side of the projector.
4. Unlock the fold mirror screws to unlock the adjustment knobs.