-37-
L
: Adjustment necessary
M
: Check necessary
Adjustments after Parts Replacement
Adjustments
Disassembly / Replaced Parts
Mirror / Light tunnel
Main board
Power
(DC) board
Fans /
Sensor (S901)
Adjustments
Mirror adjustment
L
Fan driving voltage adjustment
L
L
L
Auto-calibration (PC) adjustment *
L
Auto-calibration (Slot) adjustment *
L
Auto-calibration (Component) adjustment *
L
Auto-calibration (Video) adjustment *
L
Wind sensor calibration
L
L
L
Lens shift centering adjustment
L
Serial No. Setting **see below
L
Note on Main Board Replacement
Take the following setting when the main board is replaced.
Serial No. Setting
Each projector has an unique serial no. controlled in the factory. There are 2 ways to check this serial no. The one
is printed on the rating label on the cabinet, the other one is displayed on the "Information" on the on-screen menu.
The serial no. displayed on the on-screen menu is stored in the memory IC on the main board. When replacing
the main board or memory IC, you need to write the serial no. referring to the serial no. printed on the rating label
with the serial no. setting tool. For further details, refer to the operation manual of the serial no. setting tool [SST
LITE v1.00].
Those software are included in the service CD-ROM listed below;
PROJECTOR SERVICE TOOL CD-ROM v4.20
SERVICE CODE: 610 343 5596
When the Main Board is replaced with new one, the projector detects the clogged filter and rolls up the filter until
it ends because the wind sensor setting value in the memory IC on the new board is not setup correctly. To avoid
this operation, disable the wind sensor function temporarily following to the procedure below.
1. Enter the service mode, select group no. "
240
" and item no. "
2
". Change data value from "
1
" to "
0
". Now the
function of wind sensor is disabled.
2. After completing the "Fan driving voltage adjustment", set up to enable the function of the wind sensor. (Group
no. "
240
" , Item no. "
2
", Data value is set to "
1
")
3. Execute the adjustment "Filter calibration".
Enabling/Disabling the Wind Sensor Function
* Adjustments item indicated with * are carried out at spare parts shipment in the factory, therefore they are not required
when the main board is replaced with new one.
DS+750 Service Manual
020-000211-01 Rev. 1 (06-2009)
Содержание DS+750
Страница 1: ...DS 750 S E R V I C E M A N U A L 020 000211 01...
Страница 2: ......
Страница 47: ...45 Electrical Adjustment Test Points and Locations K66S 1 7 DS 750 Service Manual 020 000211 01 Rev 1 06 2009...
Страница 152: ...150 IC Block Diagrams L BA7078AF Sync Sep IC5321 L M62393FP DAC IC7801 DS 750 Service Manual 020 000211 01 Rev 1 06 2009...
Страница 154: ...152 IC Block Diagrams L K4S641632K SDRAM IC3401 L PW392 Scaler IC301 DS 750 Service Manual 020 000211 01 Rev 1 06 2009...
Страница 210: ......
Страница 224: ......