-51-
Electrical Adjustment
Grp / No.
Item
Function
Range
Initial
Note
201
Option (Signal) Not Used
0
FrameLock Option
Frame Lock Setting 1: Normal(PC) 0: OFF
0 - 1
1
1
Dither Enable
0: Disable 1: Enable
0 - 1
1
2
VSBEG
0 - 15
2
3
Field Sense Invert Enable
0: Disable 1: Enable
0 - 1
0
204
Simulation mode
0
PW392C Enable
0: Off, 1: On
0 - 1
0
1
PW610 Enable
0: Off, 1: On
0 - 1
0
205
Spread Spectrum
0
Enable
0 - 1
0
1
Spread Rate
0 - 300
100
2
Spread Frequency
0 - 500
150
210
Lamp Contorl
0
Dimmer SW
0:Auto 1:Manual
0 - 1
0
1
Manual Control
Lamp Power Manual Control (DIMMER_CTRL_LEVEL
0(Dark)~15(Bright))
0 - 15
0
2
DIMMER_CTRL_LEVEL1
Y Level1 Data for Dimmer
0 - 255
7
3
DIMMER_CTRL_LEVEL2
Y Level2 Data for Dimmer
0 - 255
14
4
DIMMER_CTRL_LEVEL3
Y Level3 Data for Dimmer
0 - 255
21
5
DIMMER_CTRL_LEVEL4
Y Level4 Data for Dimmer
0 - 255
28
6
DIMMER_CTRL_LEVEL5
Y Level5 Data for Dimmer
0 - 255
35
7
DIMMER_CTRL_LEVEL6
Y Level6 Data for Dimmer
0 - 255
42
8
DIMMER_CTRL_LEVEL7
Y Level7 Data for Dimmer
0 - 255
49
9
DIMMER_CTRL_LEVEL8
Y Level8 Data for Dimmer
0 - 255
56
10
DIMMER_CTRL_LEVEL9
Y Level9 Data for Dimmer
0 - 255
63
11
DIMMER_CTRL_LEVEL10
Y Level10 Data for Dimmer
0 - 255
70
12
DIMMER_CTRL_LEVEL11
Y Level11 Data for Dimmer
0 - 255
77
13
DIMMER_CTRL_LEVEL12
Y Level12 Data for Dimmer
0 - 255
84
14
DIMMER_CTRL_LEVEL13
Y Level13 Data for Dimmer
0 - 255
91
15
DIMMER_CTRL_LEVEL14
Y Level14 Data for Dimmer
0 - 255
98
16
DIMMER_CTRL_LEVEL15
Y Level15 Data for Dimmer
0 - 255
105
17
DIMMER_AVERAGE_POINT
Y Average Point
1 - 16
4
18
DIMMER_AVERAGE_DATA
Y Average Data (Read only)
-
-
19
DIMMER_LEVEL_AUTO
Current Y Level (Read only)
-
-
20
DIMMER_LEVEL_NORMAL
Dim Level at Normal
0 - 15
15
21
DIMMER_LEVEL_ECO
Dim Level at Eco
0 - 15
0
23
VOLTAGE_LEVEL
Lamp Voltage (Read only)
-
-
24
DIMMER_LEVEL_HIGH
Dim Level at High
0 - 15
15
220
Projector Error Log
0
Warning_Log_1
Latest Error log
0 - 32767
0
:
:
:
:
:
49
Warning_Log_50
50th Error log
0 - 32767
0
50
Warning_Log Reset
Log is cleared when the value is set to 10.
0 ~ 10
0
235
Shutter
0
PRE_MOTION
Shutter Warm - up Operation (0: Yes, 1: No)
0 - 1
Initial: 1 / Shipping: 0
1
CMP_TRM
Chattering Detecting Term
0 - 32767
7000
2
OUT_DLY_TRM
Output Term
0 - 32767
15000
3
CMP_CHK_CNT
Count of Information Sync
0 - 15
5
4
OPEN_DLY
Open Output Delay
0 - 63
30
5
CLOSE_DLY
Close Output Delay
0 - 63
30
6
Position Check Time
Position Check Time
1 - 255
20
7
Stop Mode
Shutter Operation in Stop Mode
0:Free, 1:Brake
0 - 1
1
8
Enable Close Cmd
Shutter Close Command
0:Disable, 1:Enable
0 - 1
1
236
Lamp Mode Switch
0
2 Lamp Mode
0 - 99
0
1
Lamp1 Mode
0 - 99
0
2
Lamp2 Mode
0 - 99
0
240
Flow Calibration
0
Flow Calibration Exe
Flow Sensor Offset Calibration Start calibration when the value
is set to 1.
0 - 1
0
DS+750 Service Manual
020-000211-01 Rev. 1 (06-2009)
Содержание DS+750
Страница 1: ...DS 750 S E R V I C E M A N U A L 020 000211 01...
Страница 2: ......
Страница 47: ...45 Electrical Adjustment Test Points and Locations K66S 1 7 DS 750 Service Manual 020 000211 01 Rev 1 06 2009...
Страница 152: ...150 IC Block Diagrams L BA7078AF Sync Sep IC5321 L M62393FP DAC IC7801 DS 750 Service Manual 020 000211 01 Rev 1 06 2009...
Страница 154: ...152 IC Block Diagrams L K4S641632K SDRAM IC3401 L PW392 Scaler IC301 DS 750 Service Manual 020 000211 01 Rev 1 06 2009...
Страница 210: ......
Страница 224: ......