-55-
Electrical Adjustment
Grp / No.
Item
Function
Range
Initial
Note
34
Eco1 Fan A Min
Fan Voltage Set at Eco1 (Min/Max) (V)
0000-9990
50
50
50
50 50 50 50 50
35
Eco1 Fan A Max
0000-9990
90
90
90 90 90 90 90 90
36
Eco1 Fan B/C Min
0000-9990
40
60
70
70 70 70 70
60
37
Eco1 Fan B/C Max
0000-9990
40
60
70
70 70 70 70
60
38
Eco1 Fan D/E Min
0000-9990
58
58
58
58 58 58 58 58
39
Eco1 Fan D/E Max
0000-9990
125 125 125 125 125 125 125 125
40
Eco1 Fan F/G Min
0000-9990
78
78
78
78 78 78 78
78
41
Eco1 Fan F/G Max
0000-9990
125 125 125 125 125 125 125 125
42
Eco1 Fan H Min
0000-9990
65
65
65 65 65 65 65 65
43
Eco1 Fan H Max
0000-9990
120 120 120 120 120 120 120 120
48
Eco2 Fan Control Min Temp
Temp Sensor Control Start/End Temp at Eco2
20-100
27
27
27
27 27 27 27
27
49
Eco2 Fan Control Max Temp
20-100
37
37
37
37 37 37 37
37
50
Eco2 Fan A Min
Fan Voltage Set at Eco2 (Min/Max) (V)
0000-9990
60
60
60 60 60 60 60 60
51
Eco2 Fan A Max
0000-9990
90
90
90 90 90 90 90 90
52
Eco2 Fan B/C Min
0000-9990
40
60
70
70 70 70 70
60
53
Eco2 Fan B/C Max
0000-9990
40
60
70
70 70 70 70
60
54
Eco2 Fan D/E Min
0000-9990
70
70
70
70 70 70 70
70
55
Eco2 Fan D/E Max
0000-9990
130 130 130 130 130 130 130 130
56
Eco2 Fan F/G Min
0000-9990
85
85
85 85 85 85 85 85
57
Eco2 Fan F/G Max
0000-9990
130 130 130 130 130 130 130 130
58
Eco2 Fan H Min
0000-9990
75
75
75
75
75 75 75
75
59
Eco2 Fan H Max
0000-9990
130 130 130 130 130 130 130 130
255
Fan Start/Cooling Setting
0
Fan A Initial Volt
Fan Start Voltage (0.1V)
0-255
70
1
Fan B/C Initial Volt
0-255
70
2
Fan D/E Initial Volt
0-255
70
3
FanF/G Initial Volt
0-255
70
4
FanH Initial Volt
0-255
70
8
Cooling Time
Cooling Time Setting (x30 sec.) 1: 30 3: 90 15: 450
1-15
3
10
Temp Error Cooling Time
Cooling Time Setting When the Temp Error occurs (x30 sec.)
1: 30 3: 90 15: 450
1-15
5
11
OnStart Cooling Start Threshold
0-100
50
12
After shutdown cooling
Cooling Operation after Shut Down (0: No, 1: Yes)
0-1
1
256
0
1
2
259
Fan Air Pressure Setting
0
Press Source Range Low
Pressure Sensor Control Range Setting (AD)
0-1024
632
1
Press Source Range High
0-1024
810
2
Press Fan Add Range High
Pressure Sensor Fan Control Add. Voltage (x0.1)
0 - 2000
0
3
Press Fan Add Range Low
0 - 2000
65
4
Temp C-A Upward High
Fan Voltage Add Upward (Sensor A-C) High
0 - 1000
23
5
Temp C-A Upward Low
Fan Voltage Add Upward (Sensor A-C) Low
0 - 1000
21
6
Temp C-A Downward High
Fan Voltage Add Downward (Sensor A-C) High
0 - 1000
20
7
Temp C-A Downward Low
Fan Voltage Add Downward (Sensor A-C) Low
0 - 1000
19
260
Auto Calibration (Common)
0
Execute Calibration
Execute Calibration when the Value is changed to 1. (For PC
White 100%)
0 - 1
0
1
Loop Count
Max Times of Calibration
1 - 30
8
2
Auto Status
Calibration Log (Read only)
0: Calibration End Correctly 1: On Adjusting 9: Calibration
Error
0 / 1 / 9
0
3
AutoWait
Waiting time
1 - 20
3
4
CHECK - Tolerance
Tolerance of Offset
1 - 255
4
5
Time out wait
Wait Time until Time out [sec.]
1 - 255
20
100 Route Switch
0: Menu
1: Input1 - RGB Analog (OnBoard - Ext.ADC)
2: Input3 - RGB Analog (Slot - Ext.ADC)
3: Input1 - RGB Analog (OnBoard - Int.ADC)
4: Input2 - YCbCr (OnBoard - Ext.ADC)
5: Input2 - YCbCr (OnBoard - Int.ADC)
6: Input2 - Video (OnBoard - Int.VDD)
0 - 6
-
261
Auto Calibration (RGB)
PW392-AFE MDL <10bits>
0
OFFSET AREA H START
Black Level Acq. Area H Start
0 - 1000
975
1
OFFSET AREA V START
Black Level Acq. Area V Start
0 - 1000
500
2
GAIN AREA H START
White Level Acq. Area H Start
0 - 1000
25
DS+750 Service Manual
020-000211-01 Rev. 1 (06-2009)
Содержание DS+750
Страница 1: ...DS 750 S E R V I C E M A N U A L 020 000211 01...
Страница 2: ......
Страница 47: ...45 Electrical Adjustment Test Points and Locations K66S 1 7 DS 750 Service Manual 020 000211 01 Rev 1 06 2009...
Страница 152: ...150 IC Block Diagrams L BA7078AF Sync Sep IC5321 L M62393FP DAC IC7801 DS 750 Service Manual 020 000211 01 Rev 1 06 2009...
Страница 154: ...152 IC Block Diagrams L K4S641632K SDRAM IC3401 L PW392 Scaler IC301 DS 750 Service Manual 020 000211 01 Rev 1 06 2009...
Страница 210: ......
Страница 224: ......