CP2220 Setup Guide
7-1
020-100476-05 Rev. 1 (05-2014)
7 Troubleshooting
This section provides information and procedures for resolving common cinema projector issues. If you cannot
resolve a cinema projector issue, contact a Christie accredited service technician.
7.1
Cinema Projector Does Not Turn On
• Verify the wall circuit breaker is on. If there is a problem with the
wall circuit breaker turning off, contact a certified electrician.
• Check the status of the LEDs on the rear corners of the cinema
projector. (
Figure 7-1
).
• Verify the LVPS has power by looking through the non-operator’s
side front access panel. One LED should be present in the lower
middle region. (
Figure 7-2
).
• On the TPC, verify in the
Operational Status
region of the
Main
panel does not indicate a PIB failure.
7.2
Lamp Does Not Ignite
• Tap
Menu
>
Advanced Setup
>
Lamp History
and verify the number of hours the lamp has operated.
Replace a lamp nearing the end of its operational life
• Tap
Menu
>
Status
and then
Interlocks
in the left pane. Check and correct all interlock failures.
• Tap
Menu
>
Status
and then
All Alarms
in the left pane. If a ballast communication error has occurred,
restart the cinema projector and turn the lamp on.
• Tap
Menu
>
Status
and then
Temperatures
in the left pane. Verify if the DMD temperatures are too high.
If the temperatures are too high, cool the cinema projector. Ensure the cinema projector is properly venti-
lated, the air filters are not blocked, and the liquid cooling reservoir has coolant.
• Listen for a clicking noise that indicates the ballast is attempting to strike the lamp. If you do not hear a
clicking noise, there might be a problem a problem with the ballast. Contact a Christie accredited service
technician to resolve the issue.
• If you hear a brief clicking noise, but the lamp does not ignite, replace the lamp.
Figure 7-1 cinema projector Status
Figure 7-2 View Power Status LEDs
LVPS Power LED
Main Input LED
Содержание CP2220
Страница 1: ...CP2220 S e t u p G u i d e 020 100476 05...
Страница 2: ......
Страница 3: ...CP2220 S e t u p G u i d e 020 100476 05...
Страница 5: ...required and in accordance with the maintenance schedule specified by Christie will void the warranty...
Страница 6: ......
Страница 10: ......
Страница 14: ......
Страница 30: ......
Страница 36: ......
Страница 52: ......
Страница 54: ......
Страница 62: ......
Страница 68: ......
Страница 69: ......