CP2220 Setup Guide
020-100476-05 Rev. 1 (05-2014)
2. Remove the knockout plate located in the bottom right corner of the front bezel. The AC supply is routed
to the terminal block through a strain relief mounted on this knockout plate.
3. Connect the AC power cables to the terminal block, beginning with the ground lead first. Use an
appropriately sized strain relief connector with the knockout plate provided to ensure adequate
environmental sealing and to prevent the cables from wear and accidentally being torn out.
NOTES: 1)
The terminal block accommodates up to an 8 AWG wire.
2)
If desired, a 90° strain relief connector can be
used to route the power cable in a downward direction.
4. Replace the knockout plate and the bottom access panel over the terminal block.
Figure 2-11
Figure 2-12