CP2220 Setup Guide
3-3
020-100476-05 Rev. 1 (05-2014)
3.2
Connect Devices to the SCCI Port
The Simple Contact Closure Port (SCCI) port is a DB-9 (male) connector is located on the PIB input panel and
is used to control a limited set of cinema projector functionality through contact closures. This table lists the
control functions available through the SCCI:
Table 3.1 SCCI Connector Pinouts
NOTE
: All SCCI inputs require a pulse input of 50ms to several seconds to operate reliably. Inputs are 5V
resistor current limited LED’s inside of optocouplers.
A “Health Output” on this connector is also provided for locations that require a cinema projector Health
Output. The output is an open-collector circuit which only draws power when the cinema projector is deemed
to be “un-healthy”. The primary use of the cinema projector Health Output is to ensure that patrons are not left
in a dark theatre due to cinema projector fault. Therefore, any fault that results in the movie playback stopping
should cause this circuit to draw power and indicate an un-healthy state. The cinema projector is always
considered to be “healthy” in Standby Mode since there is no fear of cinema projector fault causing an impact
to patrons, and there should be no patrons in the theatre at that time.
PIN
SIGNAL NAME
DIRECTION
DESCRIPTION
1
+5V Standby
Out
Current limited 5VDC supply
2
Lamp ON
In
cinema projector at
Power On
mode,
lamp is ON
3
+5V Standby
Out
Current limited 5VDC supply
4
Lamp OFF
In
cinema projector at full power, lamp is
OFF
5
+5V Standby
Out
Current limited 5VDC supply
6
Douser Closed
In
Close douser
7
Douser Open
In
Douser open
8
Health Output
Out
Open Collector Low when one of the
following interlocks is tripped or condi-
tions present:
• Lamp Door
• Lamp Blower
• Extractor
• Tamper
• Marriage
• Ballast Communication
The show will not be able to play.
Open Collector High when all inter-
locks relevant to CineLink and Lamp
are not tripped. The show is able to
play.
9
Ground
Out
Ground
Содержание CP2220
Страница 1: ...CP2220 S e t u p G u i d e 020 100476 05...
Страница 2: ......
Страница 3: ...CP2220 S e t u p G u i d e 020 100476 05...
Страница 5: ...required and in accordance with the maintenance schedule specified by Christie will void the warranty...
Страница 6: ......
Страница 10: ......
Страница 14: ......
Страница 30: ......
Страница 36: ......
Страница 52: ......
Страница 54: ......
Страница 62: ......
Страница 68: ......
Страница 69: ......