G 8 : T h e R E V E R S E T E S T M O D E C o m m a n d [ D X , L ]
This diagnostic command is used to adjust the position of the torque arms and run the projector in
slew
mode at various
speeds in the
forward
and
reverse
direction. The projector must be powered up and in the READY state.
E
NTRY
:
<CMD-G>, <8>
C
ODE
:
G8
I
NPUT
:
1. Enter a speed value of
10
on the keypad.
2. Hit the <ENTER> key.
3. Adjust R183 so that the upper torque arm sensor voltage (as
measured from the top of R150) is 0 volts ± 1 volt. This
adjusts
upper
torque arm position.
4. Adjust R136 so that the upper torque arm sensor voltage (as
measured from the top of R149) is 0 volts ± 1 volt. This
adjusts
lower
torque arm position.
Repeat Steps 1 – 4 with
speed
value inputs of
20
,
30
,
40
and
5
0
.
5. Enter a speed value of
00
to stop the projector.
6. Press the <STOP> key.
7. Enter
00
to change the projector direction to forward.
8. Press the <STOP> key.
S
TEPS
:
Repeat the above Input sequence, using R196 for the upper
torque arm and R137 for the lower torque arm.
I
NPUT
:
Enter the
DISPLAY FRAME COUNTER
( <G> , <1> )
command to return the display to normal.
S
TATUS
:
Not applicable.
Entering speed values greater than 50 can cause projector and film damage.