![Christie 174-005106-XX Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/christie/174-005106-xx/174-005106-xx_installation-and-setup-manual_2603422027.webp)
ID
Description
Quantity
A
Second dowel slot
—
B
First dowel slot
—
C
Second dowel hole
—
D
First dowel hole
—
E
M4 captive screws
4
11. Holding the receiver box, tighten the four captive screws in the receiver box.
12. Connect to power (on page 21).
13. Install the disinfecting module in the receiver box (on page 14).
14. Install the ceiling tiles removed in step 2.
15. Repeat steps 1 to 14 for each receiver box.
Mounting receiver boxes recessed in the ceiling with a bridge
Recessed mounting in the ceiling works with mounting bracket (P/N: 174-104106-XX) or an equivalent
mounting fixture.
Caution! If not avoided, the following could result in minor or moderate injury.
•
Ensure load wires and anchoring comply to local building regulations and codes.
•
Ensure load wires are connected between the receiver box, mounting structure, and the load
bearing surface (higher than the tile) according to local building regulations and codes.
A load wire must be connected between the receiver box and the load bearing surface (higher than the
tile).
1. Ensure the power is turned off at the source.
Installation and setup
CounterAct Installation and Setup Guide
27
020-103456-01 Rev. 1 (09-2021)
Copyright
©
2021 Christie Digital Systems USA, Inc. All rights reserved.
Содержание 174-005106-XX