LIBERTY® Feeding System with Electronic Sensor (ES)
General Installation Information
9
Liberty Feeding System read the installation instructions in this manual prior to beginning the installation. This
manual provides the necessary information on the installation, operation, and maintenance of the Chore-Time
feeding equipment you have purchased.
The Liberty Feeding System Control Unit uses a 348 RPM. Gearhead, delivering approximately
17 lbs
[7.7 kg]
per minute. This rating is based on feed with a density of 40 lbs per cubic foot
[640 kg
per cubic
meter]
.
Single phase 60 Hz and single and three phase 50 Hz Power Units are available for the Liberty Feeding System
Feeder.
Systems up to 300'
[91 m]
require 1/3 HP Power Units. Systems over 300'
[91 m]
require 1/2 HP Power Units.
1.Select the Suspension type.
A.
For systems up to 350'
[107 m]
General Installation Information
Laying out the Suspension System
Full Line
Suspension Kit
Swivel Pulley
8' (2.4 m)
Power Winch
Swivel Pulley
3.5" (8.9 cm)
Pulley
3' (90 cm)
Maximum
Figure 3.Suspension for systems up to 350’ [107 m]