IRIS Connect Series Engineering Manual Version 1.8
Page 35 of 40
Trouble Reported
Explanation
Input fail to communicate
A dialler input has been triggered and this event has failed to be
communicated to the ARC. Check all communication paths are working and
configuration is correct; also check with the ARC that they have no known
issues with received alarms (E.G. IRIS Poll engine IP link down).
Replace Batteries
The batteries are unhealthy and need to be replaced.
Eeprom
The dialler has a possible hardware issue and is unable to see the Eeprom.
The Eeprom stores all local parameters for protection against power failure.
Battery Status
The IRIS Connect dialler allows installers to check the current battery
status and will indicate any issues with the batteries.
About
IRIS Connect software version, GPRS/3G software version are
displayed.