Page 38 of 40 IRIS Connect Series Engineering Manual Version 1.8
10.
Specifications
Transmission paths
IRIS Connect Solo
IRIS Connect Duo
Wi-Fi
Standard
IEEE 802.11 b/g
Connection
SMA socket for Wi-Fi antenna connection
Connection
fault detection
Loss of association/data
GPRS/3G
(4G/CDMA optional
on request)
Standard
̶
Dual band GSM
900/1800 MHz
Dual band UMTS
900/2100 MHz
Connection
̶
SMA socket for GPRS/3G antenna
connection
Connection
fault detection
̶
Loss of registration with network
IP
TCP ports (outbound)
53165 (Alarms & Polling), 51292 (Diagnostic & Reflashing), 10001 (Upload/Download)
Alarm transmission
Interface to monitoring centre
IRIS Secure Apps or IRIS Management suite via EN 50136-2 pass-through mode
Dial capture interface to alarm panel
Two wire interface via RJ45 socket & terminal block
Note: Cabling must not exceed 3 meters
Serial interface to alarm panel
RS485, TTL, RS232
Note: RS232 cabling must not exceed 3 meters
PIN Inputs interface to alarm panel
Maximum input voltage range 0V to +24V
Input ‘low’ (alarm) threshold < 1V
Input ‘high’ (restore) threshold > 2V
Internal pull-up impedance 10K to 3.3V supply
Note: Cabling must not exceed 3 meters
Alarm protocols
SIA (level 1 to 3) reference SIA DC-03-1990.01(R2003.10)
Contact ID reference SIA DC-05-1999.09
Fast format (Scancom) for dial capture and serial connections
Robofon (Dial capture only)
Tamper detection reporting to
monitoring centre
Dial capture interface, Lid & back tamper, Serial interface, Pin inputs
Fault reporting to monitoring centre
External power supply fail, low battery, Transmission interface/path fault
Relay outputs
Maximum operating voltage
24V DC
Maximum current rating
100mA DC
Power supply
Supply voltage
9V to 17V DC
Typical current
78mA @ 12V DC
83mA @ 12V DC
Maximum current
1A @ 12V DC
Recommended external PSU
12V DC 1A 12 Watt DC Barrel 2.5mm centre
Note: For Radio & Telecoms Terminal Equipment Directive the power cable needs to
be no longer than 3 meters in length