Fault
code
Fault
categories
Possible
reasons
of
fault
Actions
Drive
power
is
too
small
Select a high power
drive
E006
Over-current
in
constant
speed
operation
Sudden change of load
or abnormal
Check the load or
reduce
the
Sudden
change of load
Low
AC
supply
voltage
Check the AC input
power supply
Drive
power
is
too
small
Select a high power
drive
E007
Over-voltage
during
acceleration
Abnormal
input
voltage
Check
the
input
power supply
The
rotating
motor
re-starts after the drive
stops instantly.
Avoid
re-start
after
the
drive
stops
instantly
E008
Over-voltage
during
deceleration
Too short Dec time
Prolong the Dec time
Too big load inertia
Use
big
dynamic
braking kit
Abnormal
input
voltage
Check the AC supply
voltage
E009
Over-voltage
in
constant
speed
operation
Abnormal change of
input voltage
Install input reactor
Too big load inertia
Use suitable dynamic
braking kit