SVF-G7 Series Frequency Inverter Operation Manual
Chapter 6 Functional Parameter Detail
124
F3.06
F3.06
F3.06
F3.06
Exciting
Exciting
Exciting
Exciting
iiiinductance
nductance
nductance
nductance
o
o
o
offff
sssstator
tator
tator
tator
a
a
a
and
nd
nd
nd
rrrrotor
otor
otor
otor
Default
Default
Default
Default:::: Dependent
Dependent
Dependent
Dependent on
on
on
on
drive
drive
drive
drive’’’’ssss
model
model
model
model
Setting
Setting
Setting
Setting sssscope
cope
cope
cope:::: 0.1
0.1
0.1
0.1
~
6553.5mH
6553.5mH
6553.5mH
6553.5mH
F3.07
F3.07
F3.07
F3.07
Current
Current
Current
Current
w
w
w
without
ithout
ithout
ithout lllload
oad
oad
oad
Default
Default
Default
Default:::: Dependent
Dependent
Dependent
Dependent on
on
on
on
drive
drive
drive
drive’’’’ssss
model
model
model
model
Setting
Setting
Setting
Setting sssscope
cope
cope
cope:::: 0.1
0.1
0.1
0.1
~
655.3.5A
655.3.5A
655.3.5A
655.3.5A
When the auto-learning of motor’s parameters normally ends, the setting
value from F3.03 to F3.07 will automatically update. These parameters are
the benchmarks of high-performance vector control, and directly affect the
control performance.
☞
Note: Users do not arbitrarily change the group of parameters.
F3.08
F3.08
F3.08
F3.08 Parameter
Parameter
Parameter
Parameter a
a
a
auto-learning
uto-learning
uto-learning
uto-learningDefault
Default
Default
Default:::: 0
0
0
0
Setting
Setting
Setting
Setting sssscope:
cope:
cope:
cope: 0
0
0
0
~
2
2
2
2
0: No operation
The auto-learning is banned.
1: Dynamic auto-learning
Before starting auto-learning, please ensure the motor and load being
disconnected, Reserve the motor no-load and confirm the motor in the
standstill state.
Values on the motor’s nameplate (F3.01~F3.02) must be input correctly
before starting auto-learning, otherwise, the auto-learned parameters are
not correct.
The size of Acc/Dec time (F0.10~F0.11) should be properly set according
the size of the motor’s inertia before starting auto-learning, otherwise,
the over-current fault may be caused during auto-learning.
F3.08 is set to 1, then press ENTER key, the system begins auto-learning.
Now, the LED flashing displays -TUN-, press RUN key, the LED displays TUN-0,