5. Description of Function Codes
97
Diagram 5-28 Simple PLC when used as frequency source
Code
Parameter Name
Setting Range
Default
C2-01
Simple PLC record
selection
Unit's digit: Record of power failure.
0: no record after power off
1: record after power off
Ten's digit: Record of stopping.
0: no record after stopping
1:record after stopping
00
PLC record of power failure indicates that the frequency inverter memorizes the PLC running stage and
running frequency before power failure, and frequency inverter will continue to run from the memorized
stage after it is powered on again. If the unit's digit is set to 0, the frequency inverter restarts the PLC
process after it is powered on again.
PLC record of stopping indicates that the frequency inverter records the PLC running stage and running
frequency of stop, and frequency inverter will continue to run from the recorded stage after power on again.
If the ten's digit is set to 0, the frequency inverter will restarts the PLC process after it power on again.
Code
Parameter Name
Setting Range
Default
C2-02
Running time of simple
PLC Segment 0
0.0s(h)~6553.5s(h) 0.0s
(h)
C2-03
Acceleration/deceleration
time of simple PLC
Segment 0
0~3 0
C2-04
Running time of simple
PLC Segment 1
0.0s(h)~6553.5s(h) 0.0s
(h)
C2-05
Acceleration/deceleration
time of simple PLC
Segment 1
0~3 0
C2-06
Running time of simple
PLC Segment 2
0.0s(h)~6553.5s(h) 0.0s
(h)
C2-07
Acceleration/deceleration
time of simple PLC
Segment 2
0~3 0
5. Description of Function Codes
EM11 User’s Manual
98
Code
Parameter Name
Setting Range
Default
C2-08
Running time of simple
PLC Segment 3
0.0s(h)~6553.5s(h) 0.0s
(h)
C2-09
Acceleration/deceleration
time of simple PLC
Segment 3
0~3 0
C2-10
Running time of simple
PLC Segment 4
0.0s(h)~6553.5s(h) 0.0s
(h)
C2-11
Acceleration/deceleration
time of simple PLC
Segment 4
0~3 0
C2-12
Running time of simple
PLC Segment 5
0.0s(h)~6553.5s(h) 0.0s
(h)
C2-13
Acceleration/deceleration
time of simple PLC
Segment 5
0~3 0
C2-14
Running time of simple
PLC Segment 6
0.0s(h)~6553.5s(h) 0.0s
(h)
C2-15
Acceleration/deceleration
time of simple PLC
Segment 6
0~3 0
C2-16
Running time of simple
PLC Segment 7
0.0s(h)~6553.5s(h) 0.0s
(h)
C2-17
Acceleration/deceleration
time of simple PLC
Segment 7
0~3 0
C2-18
Running time of simple
PLC Segment 8
0.0s(h)~6553.5s(h) 0.0s
(h)
C2-19
Acceleration/deceleration
time of simple PLC
Segment 8
0~3 0
C2-20
Running time of simple
PLC Segment 9
0.0s(h)~6553.5s(h) 0.0s
(h)
C2-21
Acceleration/deceleration
time of simple PLC
Segment 9
0~3 0
C2-22
Running time of simple
PLC Segment 10
0.0s(h)~6553.5s(h) 0.0s
(h)
C2-23
Acceleration/deceleration
time of simple PLC
Segment 10
0~3 0
C2-24
Running time of simple
PLC Segment 11
0.0s(h)~6553.5s(h) 0.0s
(h)
C2-25
Acceleration/deceleration
time of simple PLC
Segment 11
0~3 0
C2-26
Running time of simple
PLC Segment 12
0.0s(h)~6553.5s(h) 0.0s
(h)