Chicago Pnematic Compressors
11/2008
62 305 549 65
Page 9
9.0 COMPRESSOR ROOM
9.1 FLOOR
The floor must be even and of industrial type.
Consider the total weight of the compressor when positioning it.
9.2 VENTILATION
When the compressor is operating, the room temperature must not be higher than
104 °F
or lower than
36 °F.
If the environment is dusty it is advisable to fit a filtering panel on this opening.
The hot air ejected by the compressor may be led outside with a pipe.
This pipe must have a minimum section of
35.3 sqft
and it must not be longer than
9.8 ft.
For longer pipes an extra fan must be fitted
.
9.3 EXAMPLES OF VENTILATION OF THE COMPRESSOR ROOM
FIG. 7
FAN AIR OUTPUT
HOT AIR EJECTION
ATTENTION: REMOVABLE PIPE TO
ALLOW CLEANING OF THE
COOLER
HOT AIR PIPE