CHECK OIL LEVEL AND TOP OFF
- Switch off the compressor using the button Ref. 1 Fig. 14: the compressor will stop after running unloaded for a few
seconds.
- Turn off main power and lockout disconnect Ref. 3 Fig. 14
-
Remove the side maintenance panel using the supplied key.
-
Wait a few minutes for the foam in the sump tank to abate.
-
Check the oil level on the indicator Ref. 4 Fig. 14
-
If the oil level is under the minimum, top off.
USE OIL OF THE SAME TYPE AS THAT ALREADY IN THE COMPRESSOR; DO NOT MIX DIFFERENT TYPES OF
OIL.
BEFORE CARRYING OUT ANY OPERATION ON THE COMPRESSOR, ENSURE THAT THE ELECTRIC POWER
SUPPLY HAS BEEN DISCONNECTED.
- Slowly open the fill port Ref. 6 Fig. 14
- Top off to maximum level Ref. 4 Fig. 14, with oil of the same type in the compressor.
- Replace the cap on the fill ports Ref. 6 Fig. 14.
- Close the side maintenance panel using the supplied key
15.5 CLEANING THE FILTRATION PANEL
- Press the “STOP” button Ref. 1 Fig. 15
- Switch off the compressor
- Turn off main power and lockout disconnect Ref. 3 Fig. 15.
- Remove the filter panel Ref. 4 Fig. 15.
- Clean the filter panel with water,
do not use solvents.
- Once the operation has been completed, reassemble the filter panel.
FIG. 15
3
4
4
1
2
HP 40-50
4
HP 60
Содержание CPC 4
Страница 1: ...Instruction Manual EN CP COMPRESSOR Model CPC 40 50 60 62 305 549 65 CPC 50 ...
Страница 34: ...11 2008 Chicago Pneumatic Compressors Page 34 62 305 549 65 NOTE ...
Страница 35: ...Chicago Pnematic Compressors 11 2008 62 305 549 65 Page 35 NOTE ...
Страница 36: ...support support CPcompressor com 1 877 861 CPAC CP Compressors 1800 Overview Dr Rock Hill SC 29730 ...