20.3 CHECK THE DIRECTION OF ROTATION
- Check that all fixed panels are in their correct position.
- Remove the side maintenance guard using the supplied key (Ref. 1 Fig. 17a).
- Connect the controller to the power supply with the automatic circuit-breaker switch of the line.
- Start up the compressor pushing in sequence I button Fig. 17A and immediately after about 1 second the 0 button
Fig. 17A to stop.
- Check the motor rotation direction is the same as the arrow marked on the compressor.
ALL WORK ON THE ELECTRICALS, HOWEVER SLIGHT, MUST BE CARRIED OUT BY PROFESSIONALLY
SKILLED PERSONNEL.
- If the rotation direction is not correct, turn off the power and invert the two connections at point Ref. 2 Fig. 17a
IT IS ADVISABLE NOT TO DO ANYTHING ON THE CONTROLLER.
IF ALL THE INSTRUCTIONS FOUND IN THIS MANUAL HAVE BEEN OBSERVED THE COMPRESSOR CAN BE
STARTED.
ATTENTION: compressor start-up is delayed for a few seconds from the moment the controller is
Powered or after the scheduled stop.