15.6 CLEANING THE SUCTION FILTER OR CHANGING THE FILTER
- Press the “STOP” button Ref. 1 Fig. 15a.
- Switch off the compressor.
- Turn off main power and lockout disconnect Ref. 3 Fig. 15a.
HOT PARTS INSIDE
- Remove the side maintenance panel using the supplied key.
- Remove the cover Ref. 4 Fig. 15a.
- Remove the filter Ref. 5 Fig. 15a.
AVOID DROPPING FOREIGN BODIES INTO THE SUCTION MANIFOLD.
- Clean the filter with a jet of air, working from inside to outside.
DO NOT USE WATER OR
SOLVENTS
. Alternatively, add a new filter.
- Clean the disk on which the filter rests with a clean cloth.
- Replace the filter and the cover.
- If necessary, dispose of the old filter in accordance with local regulations.
-
Close the side maintenance panel using the supplied key.