15.3 DRAINING CONDENSATE FROM THE SUMP TANK
If the compressor experiences long pauses during which the compressor cools down, a certain amount of condensate will
gather in the sump tank. This happens, for example, when stopping overnight or on weekends.
The condensate must be drained off every 50 hours or every week. This operation may be performed only when the
compressor is cold, that is when it has been switched off for at least 8 hours.
BEFORE DRAINING THE CONDENSATE IT IS MANDATORY TO STOP THE COMPRESSOR AND DISCONNECT IT
FROM THE MAIN POWER.
Proceed as follows:
- Press the “STOP” button Ref. 1 Fig. 14
- Switch off the compressor
- Turn off main power and lockout disconnect Ref. 3 Fig. 14
- Wait for the compressor to cool down.
- Remove the side maintenance panel using the supplied key.
- SLOWLY turn on the tap Ref. 3 Fig. 14 and let the condensate flow out.
- When the first traces of oil appear, turn off the tap.
CONDENSATE MUST BE DISPOSED OF IN ACCORDANCE WITH LOCAL REGULATIONS.
- Check the oil level on the indicator Ref. 4 Fig. 14
- If the oil level is under the minimum, top off as described at point 15.4
USE OIL OF THE SAME TYPE AS THAT ALREADY IN THE COMPRESSOR; DO NOT MIX DIFFERENT TYPES OF
OIL
FIG. 14
1
3
4
5
6
2
5
Содержание CPC 4
Страница 1: ...Instruction Manual EN CP COMPRESSOR Model CPC 40 50 60 62 305 549 65 CPC 50 ...
Страница 34: ...11 2008 Chicago Pneumatic Compressors Page 34 62 305 549 65 NOTE ...
Страница 35: ...Chicago Pnematic Compressors 11 2008 62 305 549 65 Page 35 NOTE ...
Страница 36: ...support support CPcompressor com 1 877 861 CPAC CP Compressors 1800 Overview Dr Rock Hill SC 29730 ...