background image

SKU 42933 

For technical questions, please call 1-800-444-3353. 

Page 5

NEVER LEAVE TOOL RUNNING 

21. 

UNATTENDED. TURN POWER OFF. 

Don’t leave tool until it comes to a 

complete stop.

gROunDIng InStRuctIOnS

 

tO pReVent 

eLectRIc SHOck 

AnD DeAtH FROM 

IncORRect gROunDIng 

WIRe cOnnectIOn 

ReAD AnD FOLLOW tHeSe 

InStRuctIOnS:

110-120 V~ grounded tools: tools 

with three prong plugs

In the event of a malfunction or 

1. 

breakdown, grounding provides a 

path of least resistance for electric 

current to reduce the risk of electric 

shock. This tool is equipped with an 

electric cord having an equipment-

grounding conductor and a ground-

ing plug.  The plug must be plugged 

into a matching outlet that is properly 

installed and grounded in accordance 

with all local codes and ordinances.
Do not modify the plug provided – if it 

2. 

will not fit the outlet, have the proper 

outlet installed by a qualified electri

-

cian.
Improper connection of the equip-

3. 

ment-grounding conductor can re-

sult in a risk of electric shock. The 

conductor with insulation having an 

outer surface that is green with or 

without yellow stripes is the equip-

ment-grounding conductor. If repair 

or replacement of the electric cord or 

plug is necessary, do not connect the 

equipment-grounding conductor to a 

live terminal.

Check with a qualified electrician or 

4. 

service personnel if the grounding 

instructions are not completely under-

stood, or if in doubt as to whether the 

tool is properly grounded.
Use only 3-wire extension cords that 

5. 

have 3-prong grounding plugs and 

3-pole receptacles that accept the 

tool’s plug.
Repair or replace damaged or worn 

6. 

cord immediately.

125 V~ 3-prong plug and Outlet

(for up to 125 V~ and up to 15 A)

grounding 

pin

This tool is intended for use on a cir-

7. 

cuit that has an outlet that looks like 

the one illustrated above in 

125 V~ 

3-prong plug and Outlet

.  The tool 

has a grounding plug that looks like 

the plug illustrated above in 

125 V~ 

3-prong plug and Outlet

.

The outlet must be properly installed 

8. 

and grounded in accordance with all 

codes and ordinances.
Do not use an adapter to connect this 

9. 

tool to a different outlet.

Radial Arm Saw Safety Warnings

For Your Own Safety Read Instruction 

Manual Before Operating Saw

DAngeR!  coasting cutting tool 

1. 

can Be Dangerous – Apply brake 

immediately to stop cutting tool 

when the switch is turned off.

Содержание 42933

Страница 1: ...y Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools...

Страница 2: ...y Warnings 5 Essential Straight Push stick Features and Functions 7 Specifications 10 Unpacking 10 Installation 10 Operating Controls 12 Adjustments 14 Cutting Kerf Marks 15 Operation 16 Cross Cutting...

Страница 3: ...ymbol indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury CAUTION without the safety alert...

Страница 4: ...they are NOT safety glasses SECURE WORK Use clamps or a 12 vise to hold work when practical It s safer than using your hand and it frees both hands to operate tool DON T OVERREACH Keep proper 13 footi...

Страница 5: ...or without yellow stripes is the equip ment grounding conductor If repair or replacement of the electric cord or plug is necessary do not connect the equipment grounding conductor to a live terminal C...

Страница 6: ...out stopping Ripcut or Ripping A cut made paral b lel to along with the grain of the wood Crosscut or Crosscutting A cut c made perpendicular at a 90 angle to the grain of the wood Push stick A narrow...

Страница 7: ...ed push stick Push stick dimensions will vary depending on the application and user Handle Notch Must be far enough down the stick to allow a comfortable and firm grip Must be deep enough to prevent h...

Страница 8: ...n Eye protection must be ANSI approved and breath ing protection must be NIOSH ap proved for the specific hazards in the work area Industrial applications must follow 25 OSHA guidelines Maintain label...

Страница 9: ...d first be examined by a doctor and then have regular medical check ups to ensure medical problems are not being caused or worsened from use Pregnant women or people who have impaired blood circulatio...

Страница 10: ...refer to the Parts List and Assembly Drawings located at the end of this manual Secure the Radial Arm Saw to a solid 1 bench top or table by bolting or clamping the saw frame down to the bench top The...

Страница 11: ...Gear Shaft 19 and secure with the Outside Flange 16 and Bolt 15 Lock the Gear Shaft with the Stopper Pin 22 located at the front part of the Gear Case Cover 26 Using a wrench tighten the Bolt 15 over...

Страница 12: ...then squeeze and hold the Trigger For rip cutting press the green Switch in squeeze the Trigger motor starts then push up on the Lock On Button for rip cutting only to keep the motor running without h...

Страница 13: ...e Index Knob Turn the motor assem bly until it locks at the index position Lock the Yoke Pivot Clamp Handle Blade Angle The Bevel Index Knob 74 and the Bevel Lock Knob 71 are used to set the Blade ang...

Страница 14: ...lows this line from front to back If the Saw Blade moves to the right or left side of the line as it travels the entire length of the Arm loosen the Screw Clamps 137 and lightly tap on the Table left...

Страница 15: ...he plywood groove a little deep er Tighten the Carriage Lock Knob again With the machine still running loosen 10 the yoke Clamp Handle 66 and pull out the Yoke Index Knob and turn the yoke clockwise u...

Страница 16: ...e Trigger and slowly pull the Handle toward you causing the Saw Blade to cut the stock When the cut is complete release the 7 Trigger and push the Handle all the way back Wait for the Saw Blade to sto...

Страница 17: ...combines the mi tre and bevel functions Set the Saw Blade angles as previously described Continue to follow steps 4 through 9 above In Rip Cutting Ripping is the process of cutting stock along the gra...

Страница 18: ...t This function moves the Saw Blade to the front of the machine This operation is the same as in rip cutting previously described with the exception that the Pivot Yoke is turned so that the Handle is...

Страница 19: ...y a qualified technician Improper Brush maintenance can cause motor failure The Brush Caps 56 are located on each side of the motor housing Lubrication The Radial Arm Saw 5 does not require initial lu...

Страница 20: ...to the set position s Treads stripped on knob s Replace knob s Saw Blade scores workpiece not giving a good finished cut Saw Blade is leaning to one side 1 Too much play between arm and column 2 Yoke...

Страница 21: ...Bevel Lock Knob 1 72 Pressure Spring 1 1 73 C clip 1 74a Bevel Lock Knob 1 74b Carriage Lock Knob 1 75 Knob Pin 1 76 Bearing Shaft 4 77 Bearing 60029 4 78 Stopper Shaft 1 79 Thin Washer 16 2 80 Carri...

Страница 22: ...22 Record Product s Serial Number Here Note If product has no serial number record month and year of purchase instead Note Some parts are listed and shown for illustration purposes only and are not a...

Страница 23: ...SKU 42933 For technical questions please call 1 800 444 3353 Page 23 Assembly Diagram 98 167...

Страница 24: ...ons outside our facilities criminal activity improper installation normal wear and tear or to lack of maintenance We shall in no event be liable for death injuries to persons or property or for incide...

Отзывы: