Season Option Settings:
Season Option is managed by the temperature sensor. To set the season desired, do the
following:
A and C buttons:
to go from
one function list to the next
B button:
to enable/disable
the item desired
LFT button:
returns to the
Programming Screen without
saving
RT button:
saves and returns
to the Programming screen
Value set at the factory: Summer.
For the notes on the operation of the Season Option, see the “Temperature” table on
page 32.
Adjusting the brightness hysteresis frame and threshold:
In the “Sensor Thresholds” screen, only a basic adjustment of the brightness sensor is
possible. For a finer adjustment of the brightness sensor activation values, do as follows:
Namely:
- Hysteresis frame: adjust the tolerance range compared to the activation threshold set on
the brightness sensor. If the brightness threshold is adjusted at 500 and the hysteresis
frame at 250, the automation activation threshold value will be 250 (lower threshold)
and 500 (upper threshold);
- Brightness: set the brightness sensor activation threshold, that is to say the maximum
brightness value that is not to be breached in the controlled area;
- Twilight (optional): set the twilight threshold, that is to say, the brightness value in the
evening hour when you want the blinds/venetian blind or awnings to be closed. This is
activated by selecting the “Activation” item in the display.
B button:
to go from one
screen to another
A-C buttons:
to set the
values desired
LFT button:
returns to the
Programming Screen without
saving
RT button:
saves and returns
to the Programming screen
E
NG
L
IS
H
Mar 15:22
PROGRAMMING
Hysteresis
h
Sensors enabling
Timetable
8:00
Device
Season opt.
Select
Mar 15:22
SEASON OPTION
Select
Save
Winter
Summer
Mar 15:22
MAIN
Select
Save
Mode
Manual
Settings
Programming
Automation
Sensors Test
TEST
Mar 15:22
PROGRAMMING
Hysteresis
h
Sensors enabling
Timetable
8:00
Device
Season opt.
Select
Mar 15:22
HYSTERESIS/LEVELS
Save
Regolation
Hysteresis:
0250
Brightness:
0500
Twilight:
0020
Enable
Mar 15:22
MAIN
Select
Save
Mode
Manual
Settings
Programming
Automation
Sensors Test
TEST