AUTOMATIC TIMETABLE function (option to be enabled)
Enabling this function the system works in AUTOMATIC mode only within the timetable
set by the user (factory settings: 8 – 20).
- When the timetable is started the automation enables management of the brightness.
- When the timetable expires, and when the light falls below the twilight threshold, the
device is given the command to close completely (DOWN if blinds/ venetian blind, UP
if awning).
In the operation timetable the time is displayed in black; outside the timetable it is
displayed in grey.
It is always possible to control the motor manually with the A, B and C buttons. This
movement disables automatic operation for a time that may be set by the user (see
“Setting the Automatic Disable time”, page 36).
A brightness level lower than the twilight threshold temporarily disables the automation
(red hand displayed). When the timetable expires, the command is given to close, in any
case. The manual controls (A, B and C buttons) remain in any case active. To enable the
automation again, the brightness sensor must be exposed to enough light to again fall
within the hysteresis frame.
Setting the Automatic Timetable function:
To activate the Automatic Timetable function, do the following:
33
Select “Enable”; at this point it is possible to set the timetable.
Value set at the factory: 8-20.
E
NG
L
IS
H
B button:
to go from one
screen to another
A-C buttons:
to set the
values desired
LFT button:
returns to
the Programming Screen
without saving
RT button:
saves
and returns to the
Programming screen
Mar 15:22
PROGRAMMING
Hysteresis
h
Sensors enabling
Timetable
8:00
Device
Season opt.
Select
Start Time 08
00
:
End Time
20
00
:
Manual Disab. 000
Enable
Mar 15:22
TIMETABLE
Select
Save
Mar 15:22
MAIN
Select
Save
Mode
Manual
Settings
Programming
Automation
Sensors Test
TEST