background image

34

Enable the sensors:

Both sensors are factory enabled. 
To disable or enable the brightness or temperature sensors, take the following steps from 
the Main Menu:

PROGRAMMING FOR DAILY USE

Adjust the temperature and brightness sensor thresholds:

From the “System Status” screen it is possible to quickly access and adjust the temperature 
and brightness sensor thresholds. Proceed as follows:

A and C buttons: 

to go from 

one function list to the next 

B button: 

to enable/disable 

the item desired 

LFT button:

 returns to the 

Programming Screen without 

saving 

RT button: 

saves and returns 

to the Programming screen

B button: 

to go from one 

screen to another 

A-C buttons: 

to set the 

values desired 

LFT button: 

returns to the 

System Status Screen without 

saving 

RT button: 

saves and returns 

to the System Status Screen

The factory settings are the following: 

 

Brightness: 500 (from 0 to 1000)   
Temperature: 35° (from 0° C to 50° C)
For adjustment of the Brightness Sensor, see also “Adjust the hysteresis frame and the 
Brightness threshold” on the following page.
The Temperature sensor is managed by the Season Option; the threshold value indicates:
- In “SUMMER”: the maximum temperature that may be reached in the environment, 

above which the sensor commands the blind/venetian blind to close or the awning to 
open.

-  In “WINTER”: the minimum temperature that may be reached in the environment, below 

which the sensor commands the blind/venetian blind to open or the awning to close.

ATTENTION! The temperature value MUST NOT correspond to the ideal 
temperature for the room being controlled.  

E

NG

L

IS

H

Mar 15:22

PROGRAMMING

Hysteresis

h

Sensors enabling

Timetable

8:00

Device

Season opt.

Select

Mar 15:22

SENSORS ENABLING

Select

Save

Temperature

Light

Mar 15:22

MAIN

Select

Save

Mode

Manual

Settings

Programming

Automation

Sensors Test

TEST

Mar 15:22

SYSTEM STATUS

Automatic

Brightness: 0135

Temperature: 20 °C

Thresh./Main menu
Quick start

Mar 15:22

SENSORS LEVELS

Save

Regolation

Temperature: 35°C

Brightness:

 0500

Содержание Skipper Senso

Страница 1: ......

Страница 2: ......

Страница 3: ...33 Setting the Automatic Timetable function p 33 PROGRAMMING FOR DAILY USE p 34 Enable the sensors p 34 Adjust the temperature and brightness sensor thresholds p 34 Season Option settings p 35 Adjusti...

Страница 4: ...TRODUCTION Keep remote controls away from children Children should be supervised to ensure that they do not play with appliance GUARANTEE Failure to comply with these instructions annuls CHERUBINI s r...

Страница 5: ...SKIPPER Senso works with two 1 5V Alkaline batteries AAA format LR03 To replace the batteries only use equally good types Old batteries should be disposed in conformity with existing national regulati...

Страница 6: ...etter by pressing the middle key SELECT To quit position the cursor on the ENTER key and press SELECT KEYBOARD Venetian blind 28 Back key Capital letters small letters special characters Numbers and s...

Страница 7: ...uage selection Select the language you require by using the UP DOWN SELECT keys and press SAVE 3 Second screen Day Time setup Use the UP DOWN keys to set the required value Press SELECT to move from o...

Страница 8: ...0 C Thresh Main menu Quick start SYSTEM STATUS LEGEND 30 Remote control battery level Screen name Command transmission indicator Active operational mode System time Automation operational timetable if...

Страница 9: ...htness and temperature levels in the room but these do not control motor movement for exceeding the thresholds It is possible to control the motor with just the UP DOWN STOP buttons on the remote cont...

Страница 10: ...cks light sensor management if active Below the threshold No command Maintains the current temperature level set Light sensor is managed by settings WINTER snowflake Temperature level Motor command Ef...

Страница 11: ...d temporarily disables the automation red hand displayed When the timetable expires the command is given to close in any case The manual controls A B and C buttons remain in any case active To enable...

Страница 12: ...rom 0 C to 50 C For adjustment of the Brightness Sensor see also Adjust the hysteresis frame and the Brightness threshold on the following page The Temperature sensor is managed by the Season Option t...

Страница 13: ...wer threshold and 500 upper threshold Brightness set the brightness sensor activation threshold that is to say the maximum brightness value that is not to be breached in the controlled area Twilight o...

Страница 14: ...is connected to To perform the test go to the Sensors Test item on the display and directly change the threshold values The values now set will be the new remote control sensor thresholds B button to...

Страница 15: ...display remains on for a number seconds which can be set pre set value 30 seconds During the 10 minutes after being switched off the display can be reactivated by slightly pressing a key and the last...

Страница 16: ...ady be created at the moment it is turned on To enable the sensor function it is necessary to memorise the motor on the remote control with one of the procedures illustrated below To change the name o...

Страница 17: ...storing use the UP DOWN STOP keys to check whether the motor is operating correctly After checking press END PROCEDURE STORING OF OTHER REMOTE CONTROLS Consult the following scheme in order to find th...

Страница 18: ...rrectly 2 LCD remote control to be stored a Main menu Programming Device Add from STORE b After storing check if the motor operates correctly using the UP DOWN STOP keys 3 After checking press END PRO...

Страница 19: ...Status screen On Skipper LCD select the device on which you wish to proceed STORING OF THE FIRST REMOTE CONTROL ATTENTION This Programming is only necessary when the motor or receiver is installed fo...

Страница 20: ...On the Multi channel remote controls Skipper series or Giro series position yourself on the desired channel Procedure 4 To add an LCD remote control to a device created with another Cherubini remote c...

Страница 21: ...selecting the system automatically goes back to the screen NEW DEVICE To quit BACK To save the changes SAVE DELETE A DEVICE If a new device is to be memorised on Skipper Senso it is necessary to firs...

Страница 22: ...close awnings and blinds Awning UP closes and DOWN opens Blind UP opens and DOWN closes Venetian blind UP opens and DOWN closes Tilting blind UP opens and DOWN closes Tilting blind in tilt area UP les...

Страница 23: ...L FEATURES Number of channels 1 Consumption during operation 90 mA Visualization LCD RGB 1 8 graphic display Control device type Joystick Irradiated RF ERP power 1 mW Power supply 2 4V 3V DC Consumpti...

Страница 24: ...s Barbet 165 Impasse Amp re 30600 Vauvert France T l 33 0 466 77 88 58 Fax 33 0 466 77 92 32 info cherubini fr www cherubini fr CHERUBINI Iberia S L Avda Uni n Europea 11 H Apdo 283 P I El Castillo 03...

Отзывы: