G) GG: Speed setup for ejector backward 1.
H) HH: Pressure setup for ejector backward 1.
I) III.I: End-position setup for ejector backward 1.
J) JJ: Speed setup for ejector backward 2.
K) KK: Pressure setup for ejector backward 2.
L) LLL.L: End-position setup for ejector backward 2.
M) NNNNN: Setup of ejector
’
s movement counts under auto operation model.
”
1
”
will
automatically be added to the counter when ejector forward is completed.
N) PPPPP: Setup of spare ejector
’
s movement counts under auto operation model.
”
1
”
Will automatically by added to the counter when ejector forward is completed.
O) OOOO.O :Position setup for mold-opening when ejector forward while opening mold-
Function selection applied.
P) T :Ejector forward while opening mold function selection, pressing either
or
for
“
open
”
or
“
close
”
, and pushing
to complete a correction.
Q) QQQQ.Q: Position setup for mold-opening when ejector forward while opening mold
function selection is applied.
R) MMMMMMMMMMM: Function selection for ejector movements. Press
or
to
Choose one of the four models, and then press
. Code descriptions for function
selection are listed below:
R.a) Ejector not in operation :It means that ejector function selection is not in
use.
R.b) Ejector holding: Under auto operation model, ejector will not go backward until
at stays for as long as the set holding time
”
OOOO.O
”
prescribes after its forward
movement.
R.c) Ejector movement counts: Ejectors repetitively go forward and backward as per
the set value of
“
NNNNN
”
movement counts under auto operation model.
R.d) Spare ejector movement: Under auto operation model, ejectors will go
forward and then backward. When ejectors move backward to then end position of
ejector backward 1, they will then move forward. The same movement will be
repeated until the spare ejector movement counts are finished, and then ejectors
will move backward to then end position.
04/08/13