1 Operational Manual
signal .(Optional)
No. Content
Description
09
Core 1 Out L.S
When chosen as core 2 L.S function, used as core 2 out stop signal.
(Optional)
10
Nozzle Guard
Purge guard closed signal.(Optional)
11
Photo Cell
Photocell detects signal at auto mode.
12
Spare Spare
13
Spare Spare
14
Lubrication surface in
sufficient
Lubrication oil level detecting signal, “ON” means short of oil.
15
Spare Spare
16
Spare Spare
17
Spare Spare
18
Spare Spare
19
Spare Spare
20
Spare Spare
21
Spare Spare
22
Spare Spare
23
Ejector Back Confirm
Hydraulic Ejector returns Signal.
24
Spare Spare
25
Spare Spare
26
Mold injector returns
Ejector backward stop proximity switch signal.
27
M.T. Motor Overload
Mold adjustment’s motor overload signal.
28
Hyd. Motor Overload
Pump motor overload signal.
29
Spare Spare
30
Mold Screw Count
Signal
Mold Screw counter signal input .(Optional)
31
Mold Ad Count Sig.
Mold height adjustment signal input.
32
Inj. Front Door L.S
Input signal “OFF” means robot and injection machine connected.
33
Inj. Rear Door L.S
Robot interlock signal, when “ON” mode open1 close in allowed.
34
Clamp Cyl. Back Co.
Interlock input between robot and ejector, when “ON” ejector
forward is allowed.
35
Mold Close Confirm
Confirms signal of part taken- out by robot.
36
Mold Screw-In L.S
Mold Screw forward stops L.S signal.
04/08/13
106