Move cursor to set parameter of opening mold. Key in desired digits and press
to complete a
correction. Code descriptions of menu 33 are as follows:
A) AA: Speed Setup for Accumulator Pressurized .(optional)
B) BB: Pressure Setup for Accumulator Pressurized .(optional)
C) CC: Speed Setup for Hydraulic Nozzle. (optional)
D) DD: Pressure Setup for Hydraulic Nozzle. (optional)
E) EE: Speed Setup for Special Mold-closing Low Pressure. (optional)
F) FF: Pressure Setup for Special Mold-closing Low Pressure. (optional)
G) GG: spare Speed Setup
H) HH: Spare Pressure Setup
I) II: Speed Setup for Booster Cylinder Mold Adjustment
J) JJ: Pressure Setup for Booster Cylinder Mold Adjustment
K) KK: Pressure Relief Speed Setup for Positioning Cylinder
L) LL: Pressure Relief Pressure Setup for Positioning Cylinder
M) MM: Speed Setup for Auto Clamping Adjustment
N) NN: Pressure Setup for Auto Clamping Adjustment
O) OO: Speed Setup for Positioning Cylinder Forward
P) PPL Pressure Setup for Positioning Cylinder Forward
Q) QQ: Speed Setup for Hydraulic Mold Adjustment Forward
R) RR: Pressure Setup for Hydraulic Mold Adjustment Forward
S) SS: Speed Setup for Hydraulic Mold Adjustment Backward
T) TT: Pressure Setup for Hydraulic Mold Adjustment Backward
U) UU: Spare Speed Setup
V) VV: Spare Pressure Setup
W) WW: Spare Speed Setup
X) XX: Spare Pressure Setup