386950CE6CD (07—08)
5
Fig. 6
OPERATION
4. Plug machine’s power cords into grounded wall
outlets on separate circuits (Figure 3). Green
circuit indicator light on switch panel illuminated
confirms connection to separate circuits.
FOR SAFETY: Do not operate machine unless
cord is properly grounded.
FOR SAFETY: Do not operate machine with the
use of an extension cord.
5. Secure recovery tank lid in place.
MACHINE OPERATION
FOR SAFETY: Do not operate machine unless
entire operator manual is read and understood.
PRE-OPERATION
1. Inspect power cord for damage.
2. Turn on empty-out pump (Figure 4). The
discharge pump will not come on until the level
inside the recovery tank activates the float switch.
Note: the “Auto Discharge” switch must be turned
on in order for the discharge pump to cycle on
and off.
3. Turn on water faucet supplying water to the
machine.
CLEANING TILE
1. Activate the pressure pump and both vacuum
switches (Figure 5).
2. Apply cleaning chemicals to the surface to be
cleaned with a separate application sprayer.
Follow chemical manufacturers instructions for
selection of chemical and dwell time before
pressure rinsing with this machine.
ATTENTION: This machine is designed to deliver
high pressure fresh water to the tile surface and
extract emulsified soil. This model is not
designed to mix chemicals with fresh water. Any
attempt to do this could damage fresh water
pump.
3. Take hard surface or tile cleaning tool in hand
and move in the direction that compliments tool
design intermittently spraying rinsing solution.
WHILE OPERATING
1. Periodically check for excessive foam buildup in
recovery tank. Use a recommended foam control
solution to prevent vacuum motor damage.
Warning: Flammable materials or reactive
metals can cause an explosion or fire. Do not
pick up.
ATTENTION: Excessive foam buildup will not
activate the float shut-off screen.
ATTENTION: Discharge pump will not pump foam.
Use a defoamer.
DRAINING RECOVERY TANK
1. Turn off machine after majority of water has been
pumped out by discharge pump.
2. Insert supplied 45º elbow in drain valve. Place a
bucket below it and slowly pull up on handle
(Figure 6).
GROUNDED OUTLET
(3 hole)
GROUNDING
PIN
Fig. 3
Fig. 4
Fig. 5