386950CE6CD (07-08)
4
OPERATION
MACHINE COMPONENTS
1. Vacuum
Inlet
2. Solution Hose Connector
3. Discharge
Connector
4. Manual
Drain
5. 12”
Wheels
6. Vacuum
Lid
7. Handle
8. Recovery
Tank
9. Mains
Circuit
Breakers
10. Discharge Pump Switch
11. Vacuum #1 Switch
12. Vacuum #2 Switch
13. Freeze Protection Drain Nozzle
14. Pressure Adjustment Valve
15. Water Input Connector
16. Pressure Pump Switch
MACHINE SETUP
1. Carefully check carton for signs of damage.
Report damages at once to carrier. The machine
is shipped fully assembled and is ready for use.
2. Connect hoses and tool to be used. Attach a ¾”
garden hose to the discharge connector on the
back of the machine. An inline filter is
recommended to prevent excessive lint and
debris from entering tank and fouling discharge
pump. Attach a second garden hose to the input
connector (Figure 1).
3. Look inside recovery tank and be certain that
submersible pump is secured properly to bracket
on the bottom of the tank (Figure 2). Take note of
the space between the case of the flood pump
and the attached stainless steel bracket. Lower
the pump so this space engages the bracket
mounted in the bottom of the recovery tank. Also
be certain that nothing is obstructing the free
movement of the float switch.
WARNING: Do not vacuum up flammable
materials as they could cause an explosion or
fire.
Fig. 1
Fig. 2
1
3
6
8
2
9
11
4
5
7
10
16
12
13
14
15