OPERATION 

SAFETY PRECAUTIONS 

This machine is intended for commercial use. It is 
designed to clean tile, grout and hard surfaces and 
then pump recovered solution away from the machine. 
It is not constructed for any other use.  

All operators must read, understand and practice the 
following safety precautions. 

The following safety alert symbols are used throughout 
this manual as indicated in their description: 

  WARNING: To warn of hazards or unsafe 

practices which could result in severe personal 
injury or death. 

FOR SAFETY: To identify actions which must be 
followed for safe operation of equipment. 

The following information signals potentially dangerous 
conditions to the operator or equipment. 

FOR SAFETY: 

1.  Do not operate machine: 
 

– 

Unless trained and authorized. 

– 

Unless operator manual is read and 
understood. 

– 

Around explosive or flammable vapors. 

 

– 

To extract flammable or explosive liquids. 

 

– 

With damaged cord or plug. 

 

If not in proper operating condition. 

 

Unless cord is properly grounded. 

 

– 

As a dry vacuum. 

 – In 

standing 

water. 

 

– 

With the use of an extension cord. 

2. Before 

operating 

machine: 

 

– 

Make sure all safety devices are in place 
and operate properly. 

3. When 

using 

machine: 

 

– 

Do not run machine over cord. 

 

– 

Do not pull machine by plug or cord. 

 

– 

Do not pull cord around sharp edges or 
corners. 

 

– 

Do not unplug by pulling on cord. 

 

– 

Do not stretch cord. 

 

Do not handle plugs with wet hands. 

 

Do not allow water or foam to enter 
vacuum. Float ball is not activated by foam. 
Damage not covered by warranty will 
result. 

 

– 

Keep cord away from heated surfaces. 

 

Report machine damage or faulty operation 
immediately. 

 

Use defoamer to protect vacuums. If foam 
exits machine turn it off immediately. 

 

Be certain submersible pump is secured in 
bottom of tank. 

 

Connect hoses before turning on pump. 

4.  Before leaving or servicing machine: 

 

Turn off machine. 

 

Unplug cord from wall outlet. 

 

Drain all recovered solution from tank. 

5.  When servicing machine: 

 

Unplug cord from wall outlet. 

 

Avoid moving parts. Do not wear loose 
jackets, shirts, or sleeves. 

 

Use manufacturer supplied or approved 
replacement parts. 

 

Have service performed by authorized 
service person. 

   WARNING: Hazardous Voltage. Shock or 

electrocution can result. Always unplug machine 
before servicing. 

   WARNING: Flammable materials can cause 

an explosion or fire. Do not vacuum into tank. 

   WARNING: Flammable materials or reactive 

metals can cause an explosion or fire. Do not pick 
up.  

   WARNING: Contents of solution hoses may 

be under pressure even after pump is off. 

   WARNING: Appliance is not intended for 

persons with reduced capabilities or children.  

 

GROUNDING INSTRUCTIONS 

Machine must be grounded. If it should 
malfunction or breakdown, grounding provides a 
path of least resistance for electrical current to 
reduce the risk of electrical shock. This machine is 
equipped with a cord(s) that must have plugs fitted 
for the coun try of use.. The plug must be plugged 
into an appropriate outlet that is properly installed 
in accordance with all local codes and ordinances. 
Do not remove ground pin; if missing, replace plug 
before use. International models will have different 
cord ends.

 

GROUNDED OUTLET 

           (3 HOLE)

GROUNDING 
        PIN 

Содержание 386950CE6CD

Страница 1: ... 01 07 08 386950CE6CD Horizon Tile Cleaning Machine Model No 386950CE6CD 15 gal Tile Cleaner KLEENRITE 1122 MAPLE STREET MADERA CA 93637 U S A FAX 1 559 673 5725 CUSTOMER SERVICE 1 800 241 4865 Operator and Parts Manual ...

Страница 2: ...Parts and supplies may be ordered by phone or mail from any authorized parts and service center distributor or directly from Kleenrite This machine will provide excellent service However the best results will be obtained at minimum costs if The machine is operated with reasonable care The machine is maintained regularly per the maintenance instructions provided The machine is maintained with manuf...

Страница 3: ...Damage not covered by warranty will result Keep cord away from heated surfaces Report machine damage or faulty operation immediately Use defoamer to protect vacuums If foam exits machine turn it off immediately Be certain submersible pump is secured in bottom of tank Connect hoses before turning on pump 4 Before leaving or servicing machine Turn off machine Unplug cord from wall outlet Drain all r...

Страница 4: ...rden hose to the discharge connector on the back of the machine An inline filter is recommended to prevent excessive lint and debris from entering tank and fouling discharge pump Attach a second garden hose to the input connector Figure 1 3 Look inside recovery tank and be certain that submersible pump is secured properly to bracket on the bottom of the tank Figure 2 Take note of the space between...

Страница 5: ...eparate application sprayer Follow chemical manufacturers instructions for selection of chemical and dwell time before pressure rinsing with this machine ATTENTION This machine is designed to deliver high pressure fresh water to the tile surface and extract emulsified soil This model is not designed to mix chemicals with fresh water Any attempt to do this could damage fresh water pump 3 Take hard ...

Страница 6: ... machine unplug cords from wall outlet DAILY MAINTENANCE Every 4 hours of operation 1 Empty and rinse out recovery tank thoroughly 2 Remove float shut off screen from recovery tank and clean Figure 8 9 3 Wipe off power cord and check for damage Replace if necessary Coil cord neatly after use 4 Clean machine with an all purpose cleaner and damp cloth 5 Unlatch locking arms of bayonet coupler attach...

Страница 7: ...4 Unscrew clear bowl on incoming water filter and clean filter screen Reassumble filter assembly STORING MACHINE 1 Before storing machine be certain to drain and rinse tank 2 Store machine in a dry area in an upright position 3 Open recovery tank lid to promote air circulation RECOMMENDED STOCK ITEMS Refer to Parts List section for recommended stock items Stock items are clearly identified with a ...

Страница 8: ...not fully engaged Connect quick couplers Faulty pump head Contact Service Center Flood pump does not work Faulty switch or wiring Contact Service Center Float switch tangled in cord Untangle cord in vacuum tank Filter screen clogged Clean filter screen under flood pump Output of flood pump disconnected Connect quick coupler in waste tank Flood pump does not discharge fast enough Small diameter gar...

Страница 9: ...l SOLUTION PUMP 230V 82 7 BAR 1200 PSI 7 6A DISCHARGE PUMP 230 V 94 6 LPM 25 GPM 2 5 A VACUUM MOTOR 2 2 STAGE PARALLEL 2 230V 3 8 A 874W SEALED WATER LIFT 2337 mm 92 in 5 66CMM 200 CFM TOTAL POWER CONSUMPTION CIR 1 220V 8 8A 1936W CIR 2 220V 7 6A 1672W POWER CORDS 2 7 6m 25 ft 3 12 DECIBEL RATING 3 METERS 10 FT FROM MACHINE ON CARPET 68 db A 787 mm 31 in 450 mm 17 7 in 939 mm 37 in 978 mm 38 5 in ...

Страница 10: ...386950CE6CD 07 08 10 ELECTRICAL DIAGRAM 386950CE6CD 230 V WIRING DIAGRAM ...

Страница 11: ...386950CE6CD 07 08 11 PARTS LIST 386950CE6CD TANK GROUP ...

Страница 12: ...GE HZN ROTO CHEM DRY 1 Part Description Qty J 49BLUGRNT LID MEGA E3 ROTO BLUGRNT 1 J 57 SPACER ROTO 1 5 OD X 1 0 ID 1 J 57 5 SPACER ROTO 3 OD X 2 4 ID 1 K 05 8 THERMAL CRCT BRKR EDGE 13AMP 2 K 16 85A NUT NYLON BELL MOUTH 13 10MM 2 K 16 92 BUSHING RELIEF 3 8 NPT 1 K 17 5 CLAMPS NYLON CABLE 3 8 2 K 21WGRY SWITCH SPST WTR RESIS GRY 4 K 28 05 TIE WIRE NYLON 10 SCREW 1 K 28 1 TIE WRAP 8 LONG NATURAL 3 ...

Страница 13: ...386950CE6CD 07 08 13 PARTS LIST 386950CE6CD BASE GROUP ...

Страница 14: ...04 14 HOSE PLS 38 1 2 1 4MSV X 3 8MSV 1 F 09 Q C 1 4 PLUG BR SHUT OFF 3 F 11 Q C 1 4 SOC BR SHUT OFF 3 F 11INSUL BLUE 71 4 QC SOC BR S O INSUL BLUE 1 F 12 QC 3 8 PLUG BR ST TH X 3 8FPT 1 F 14 5 QC 3 8 SOC BR ST TH X 3 8MPT 1 G 25 15 VALVE BALL 2 WAY 1 4 FPT 1 G 37 VALVE VAC SHUT OFF DUAL 1 G 46 12 VALVE UNLOADER 1200 PSI 1 J 45BLK PMP MNT DRLD 2 VAC SILNCE BLCK R 1 J 46 5BLK MANFLD BLWR INTAKE 2 R...

Страница 15: ...edit has been established prior to the request the part will be shipped on an Open Account basis part plus freight A Return Authorization must be requested at the time of order so that the suspected defective part can be returned freight prepaid to Kleenrite for warranty consideration If after receiving the part Kleenrite determines that the part has a manufacturing defect and can be repaired the ...

Страница 16: ...han genuine Kleenrite parts will immediately void this and all warranties Filters brass fittings seals o rings and quick disconnects are considered expendable in normal use and are not covered by this warranty Dry cleaning solvents cannot be used in the HORIZON This warranty shall not cover any HORIZON machine housing part or assembly if there is evidence of misuse alteration owner neglect lack of...

Страница 17: ...han genuine Kleenrite parts will immediately void this and all warranties Filters brass fittings seals o rings and quick disconnects are considered expendable in normal use and are not covered by this warranty Dry cleaning solvents cannot be used in the HORIZON This warranty shall not cover any HORIZON machine housing part or assembly if there is evidence of misuse alteration owner neglect lack of...

Отзывы: