Chapter X. iSCSI PDU Offload Target
Chelsio Unified Wire for Linux
163
DataPDUInOrder
“Yes”
“No”
“Yes”
No
To indicate the data PDUs with
sequence must be at continuously
increasing order or can be in any
order.
Chelsio only supports “Yes”.
DataSequenceInOrder
“Yes”
“No”
“Yes”
No
To indicate the Data PDU sequences
must be transferred in continuously
non-decreasing sequence offsets or
can be transferred in any order.
Chelsio only supports “Yes”.
ErrorRecoveryLevel
0 to 2
0
No
To negotiate the recovery level
supported by the node.
Chelsio only supports 0.
HeaderDigest
“None”
“CRC32C”
“None”
Yes
To enable or disable iSCSI header
Cyclic integrity checksums.
DataDigest
“None”
“CRC32C”
“None”
Yes
To enable or disable iSCSI data Cyclic
integrity checksums.
AuthMethod
“CHAP”
and
“None”
“None,
CHAP”
Yes
To choose an authentication method
during login phase.
TargetName
“<target
name>”
No
A worldwide unique iSCSI target
name.
Target only.
TargetAlias
“<target
alias>”
No
A
human-readable
name
or
description of a target. It is not used as
an identifier, nor is it for authentication.
Target only.
MaxRecvDataSegmentLengt
h
512 to
16777215
(2
24
- 1)
8192
No
To declare the maximum data
segment length in bytes it can receive
in an iSCSI PDU.
OFMarker
“Yes”
“No”
“No”
No
To turn on or off the initiator to target
markers on the connection.
Chelsio only
supports “No”.
IFMarker
“Yes”
“No”
“No”
No
To turn on or off the target to initiator
markers on the connection.
Chelsio only supports “No”.
OFMarkInt
1 to 65535
2048
No
To set the interval for the initiator to
target markers on a connection.
IFMarkInt
1 to 65535
2048
No
To set the interval for the target to
initiator markers on a connection.
Chelsio Entity Settings
Description
Chelsio entity parameters pass control information to the Chelsio iSCSI module. The parameters
are specific to Chelsio’s implementation of the iSCSI node (target or initiator) and are unique for
each entity block. The parameters consist of information that can be put into three categories:
1. Challenge Handshake Authentication Protocol (CHAP).
2. Target specific settings. All of the following parameters can have multiple instances in one
target entity block (i.e., they can be declared multiple times for one particular target):
•
Portal Group
•
Storage Device
Содержание Terminator 6
Страница 1: ...Chelsio Unified Wire for Linux i...
Страница 15: ...Chapter I Chelsio Unified Wire Chelsio Unified Wire for Linux 15 I Chelsio Unified Wire...
Страница 51: ...Chapter II Network NIC TOE Chelsio Unified Wire for Linux 51 II Network NIC TOE...
Страница 70: ...Chapter III Virtual Function Network vNIC Chelsio Unified Wire for Linux 70 III Virtual Function Network vNIC...
Страница 82: ...Chapter IV iWARP RDMA Chelsio Unified Wire for Linux 82 IV iWARP RDMA...
Страница 99: ...Chapter V iSER Chelsio Unified Wire for Linux 99 V iSER...
Страница 107: ...Chapter VI WD UDP Chelsio Unified Wire for Linux 107 VI WD UDP...
Страница 119: ...Chapter VII WD TOE Chelsio Unified Wire for Linux 119 VII WD TOE...
Страница 125: ...Chapter VIII NVMe oF Chelsio Unified Wire for Linux 125 VIII NVMe oF...
Страница 135: ...Chapter IX LIO iSCSI Target Offload Chelsio Unified Wire for Linux 135 IX LIO iSCSI Target Offload...
Страница 148: ...Chapter X iSCSI PDU Offload Target Chelsio Unified Wire for Linux 148 X iSCSI PDU Offload Target...
Страница 187: ...Chapter XI iSCSI PDU Offload Initiator Chelsio Unified Wire for Linux 187 XI iSCSI PDU Offload Initiator...
Страница 198: ...Chapter XII Crypto Offload Chelsio Unified Wire for Linux 198 XII Crypto Offload...
Страница 211: ...Chapter XIII Data Center Bridging DCB Chelsio Unified Wire for Linux 211 XIII Data Center Bridging DCB...
Страница 223: ...Chapter XIV FCoE Full Offload Initiator Chelsio Unified Wire for Linux 223 XIV FCoE Full Offload Initiator...
Страница 230: ...Chapter XIV FCoE Full Offload Initiator Chelsio Unified Wire for Linux 230...
Страница 235: ...Chapter XV Offload Bonding Chelsio Unified Wire for Linux 235 XV Offload Bonding...
Страница 258: ...Chapter XVIII Offload IPv6 Chelsio Unified Wire for Linux 258 XVIII Offload IPv6...
Страница 265: ...Chapter XIX WD Sniffing and Tracing Chelsio Unified Wire for Linux 265 XIX WD Sniffing and Tracing...
Страница 272: ...Chapter XX Classification and Filtering Chelsio Unified Wire for Linux 272 XX Classification and Filtering...
Страница 297: ...Chapter XXI OVS Kernel Datapath Offload Chelsio Unified Wire for Linux 297 XXI OVS Kernel Datapath Offload...
Страница 311: ...Chapter XXII Ring Backbone Chelsio Unified Wire for Linux 311 XXII Ring Backbone...
Страница 317: ...Chapter XXIII Traffic Management Chelsio Unified Wire for Linux 317 XXIII Traffic Management...
Страница 329: ...Chapter XXIV DPDK Driver Chelsio Unified Wire for Linux 329 XXIV DPDK Driver...
Страница 347: ...Chapter XXV Unified Boot Chelsio Unified Wire for Linux 347 XXV Unified Boot...
Страница 357: ...Chapter XXV Unified Boot Chelsio Unified Wire for Linux 357 iv Boot to EFI Shell...
Страница 427: ...Chapter XXVI Appendix A Chelsio Unified Wire for Linux 427 XXVI Appendix A...