Electric Induction hobs Chef’s
EH-DIH386 & EH-MIX386
27
18. Error output, error handling
General error codes display
For common errors, scheme 3 is used: during the first phase it indicates an „E“ on the
left (21), an „ r” on the right (23) and in the second phase it indicates the two-digit error
number.
General errors
General
Errocode
Display
comment
0x22
Er22
HW Error / the keys don’t work when key voltage < 1,2V. when
dummy key (empty key) voltage > 2,3V.
0x13
Er13
EEPROM data incorrect (outer circuit configuration).
0x20
Er20
Flash error.
0x03
Continous pushing of keys, this error is in your specification
described with another visualisation.
0x04
E4
Temperature on TC board over 95 degrees (displays 5 sec).
Temperature on power board over 100 degrees (displays 5
sec).
Power board NTC (P1< 2,18V (80C), no error indication). P2<
1,54V.
When TC NTC voltage : P2 < 1,68V.
0x26
Er26
Relay voltage too high when switched off or too low when
switched on (PWM feed back voltage).
When TC is off : voltage > 2,46V.
When TC is on and PWM off : voltage < 2,46V.
When TC is on and PWM on : voltage > 2,46V.
0x36
Er36
NTC out of valid value, may be NTC is destroyed.
0x37
Er37
Faulty feedback of shift register signals to the segment or
relay activation (different display on Domino TC).
Cooking zone specific errors
Cooking zone specific errors displays 5 secs.