40
LAVA STONE GRILL - EASY 700
Instructions for qualified fitters
UM300010
- 10/2019
©
Copyright 2019
6
6-6 Gas Connection
Before connecting the appliance, make sure that the data on the identification plate corresponds to that of
the gas supply network. If the gas indicated on the plate is not the same available in the premises, follow
the instructions in chap.
Adjustment for operation with different gases
-
Connection to the gas supply network must always be carried out using rigid or flexible metal piping with
proportionate cross-section, inserting a sealing gasket suitable for gas use.
- Connections between the 3/4"G piping from the appliance and the gas pipes should preferably be carried
out using a three-piece metal joint, in order to facilitate connection and dismantling if necessary.
-
Seal the joint threads using TFE tape (tetrafluoroethylene) or other materials declared by their
manufacturers as being suitable for LPG too.
- Always insert a cut-off tap between the appliance and the gas supply pipes, in a position that makes it
easy to handle and turn off after use.
- During connection between the gas piping and the appliance, make sure you do not cause any kind of
stress to the appliance itself.
- Gaskets must be metallic or of other elastic materials that cannot be altered by the gas distributed.
-
Copper piping junctions must be realized using mechanical couplings without gaskets or putty.
- After connection to the gas supply, check the absence of any leaks in the joints and connections using
water and soap or a suitable leak detection product.
6.6.1 Characteristics and requirements of the gas supply network
The appliance is started at the nominal capacity of the gas used with the nozzles indicated in par.
and nozzle specifications and adjustments depending on the type of gas used
on page
Depending on the gas used, the supply pressure must fall within the following values;
do not connect the
appliance if the pressure values are different
.
GAS
Nominal pressure (mbar)
Minimum pressure (mbar)
Maximum pressure (mbar)
G20 (methane)
20
17
25
G30 (LPG)
30
28
50
G31 (LPG)
37
28
50
Tab. 8 Intended supply pressures
The appliance is delivered for use with natural gas, G20 (methane gas) at a pressure of 20 mbar; check the
category of the country in which it is to be installed
Tab. 10 Gas category and pressure
.
If the gas indicated on the plate is not the same available in the premises, follow the instructions in chap.
Adjustment for operation with different gases
.
Содержание EASY 700
Страница 4: ...4 LAVA STONE GRILL EASY 700 UM300010 10 2019 Copyright 2019 This page intentionally left blank...
Страница 11: ...11 LAVA STONE GRILL EASY 700 Technical information UM300010 10 2019 Copyright 2019 2 2 TECHNICAL INFORMATION...
Страница 15: ...15 LAVA STONE GRILL EASY 700 Safety information UM300010 10 2019 Copyright 2019 3 3 SAFETY INFORMATION...
Страница 49: ...49 LAVA STONE GRILL EASY 700 Tables and annexes UM300010 10 2019 Copyright 2019 7 7 TABLES AND ANNEXES...
Страница 52: ......