Grouping Multiple Antennas
Larger aisles are able to be covered using a Sync configuration. Aisle widths of any 1m increment
are possible. The 3m configuration features an F10, 2 meter system and a single 1 meter system.
Similarly, the 5m layout features two (2) F10, 2 meter systems and the standard F10 antenna.
Multiple electronics enclosures and power supplies are required, in this case, and the system
electronics must be configured for operation as a single unit. Refer to the
“Wiring Between
Systems for Sync”
section.
Multiple floor trenches are cut with each length of ENT tubing (conduit) spaced 5.1 cm [2in] from
the next closest to reduce RF interference.
Although grouping multiple installation kits together is possible, it requires approval from
Checkpoint’s Product Management. Feasibility is confirmed during the initial planning stage
known as the “Site Survey.” If the Site Survey was already performed and at present you are
prepared with installation-specific details, please skip to
Chapter 3: Physical Installation
.
2 x 1 Meter Configuration
When necessary, two (2) standard F10, 1meter systems are connected to the same electronics
enclosure in a 2 x 1 meter configuration. The common application of the F10, 2 x 1 meter
configuration is in a grocery store or large department store. This setup allows EAS coverage
of many store checkout aisles, as well as single-door entrance / exit layouts. Each 1m antenna
assembly is fitted with a Matching Board. The layout minimizes the total number of electronics
enclosures needed when multiple F10 systems are used.
Figure 1.6
F10, 2 x 1 Meter System Diagram