Korg Polysix MIDI Interface
Korg Polysix MIDI Interface
Korg Polysix MIDI Interface
Korg Polysix MIDI Interface
P6
P6
P6
P6----M
M
M
M Installation
Installation
Installation
Installation Manual
Manual
Manual
Manual
8
88
8----427 / v. 1.00
427 / v. 1.00
427 / v. 1.00
427 / v. 1.00
Copyright © 2021 CHD Elektroservis. All rights reserved.
No part of this publication may be reproduced in any form without the written permission of CHD Elektroservis.
11
11
11
11
Fig. 2.5.3
Fig. 2.5.3
Fig. 2.5.3
Fig. 2.5.3
Fig. 2.5.4
Fig. 2.5.4
Fig. 2.5.4
Fig. 2.5.4
Split up free end of the cable (by ripping or cutting) to individual wires and adapt their lengths as necessary
during the cable installation. Stripe ends of all wires in length about 2 mm and tin them before they are
connected to the instrument. Individual control signals wires must be connected accordingly to the table 2 (also
see figs. 2.5.1, 2.5.2, 2.5.3 and 2.5.4). Wire Nr. 1 (terminal) is signed with red color.
Table 2
Table 2
Table 2
Table 2 –
––
– Connection of 16
Connection of 16
Connection of 16
Connection of 16----core ribbon cable to KLM
core ribbon cable to KLM
core ribbon cable to KLM
core ribbon cable to KLM----366 board
366 board
366 board
366 board
Wire Nr.
Wire Nr.
Wire Nr.
Wire Nr. Signal
Signal
Signal
Signal
Connector /
Connector /
Connector /
Connector /
Pad Nr.
Pad Nr.
Pad Nr.
Pad Nr.
Remark
Remark
Remark
Remark
Wire Nr.
Wire Nr.
Wire Nr.
Wire Nr. Signal
Signal
Signal
Signal
Connector /
Connector /
Connector /
Connector /
Pad Nr.
Pad Nr.
Pad Nr.
Pad Nr.
Remark
Remark
Remark
Remark
1
DB0
CN04 / 9
Red signed wire
9
FCMO
(CN17 /3)
To lead of R51 resistor
2
DB1
CN04 / 10
10
FCMI
CN17 / 3
To freed pad
3
DB2
CN04 / 11
11
+5V
4
DB3
CN04 / 12
12
+5V
CN01 / 2
Both 11 and 12 wires
to the same pad
5
DB4
CN04 / 13
13
GND
6
DB5
CN04 / 14
14
GND
CN01 / 3
Both 13 and 14 wires
to the same pad
7
DB6
CN04 / 15
15
-5V
8
DB7
CN04 / 16
16
-5V
CN01 / 4
Both 15 and 16 wires
to the same pad
a) Wires from Nr. 1
6
66
6
to Nr. 8 of the 16-core ribbon cable are connected to pins 9 to 16 of CN04 connector as
shown in table 1. Since solder pads of the CN04 connector are not accessible directly (they are on bottom side
of the KLM-366 board), the wires are soldered to some via-pads on the board what conforms to the pins of the
CN04 connector (fig. 2.5.5).
b) Unsolder upper lead of R51 resistor from the KLM-366 board (fig. 2.5.6).
Fig. 2.5.5
Fig. 2.5.5
Fig. 2.5.5
Fig. 2.5.5
Fig. 2.5.6
Fig. 2.5.6
Fig. 2.5.6
Fig. 2.5.6
c) Solder wire Nr. 10 of the ribbon cable to the freed soldering pad (fig. 2.5.7)
d) Place heat-shrink insulation tube
φ
4 mm (from the interface accessory) on the wire Nr. 9 of the ribbon cable
and solder the wire Nr. 9 to freed lead of the R51 resistor (fig. 2.5.8).
6
66
6
Wire Nr. 1 is signed with red color.