![Chauvin Arnoux Green TEST-FTV 100 Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/chauvin-arnoux/green-test-ftv-100/green-test-ftv-100_user-manual_2594607036.webp)
GREEN TEST-FTV 100
English
Page 36 sur 47
10. TECHNICAL CHARACTERISTICS OF THE
INSTRUMENT
WARNING, DANGER!
Reference conditions: 23°C
±
3°C; 45-75%
MONITOR
High-luminosity digital colour LCD
display area
5,7” (diagonal).
resolution
320 (W) x 240 (H) pixels.
contrast factor
300:1
luminosity
400cd
/
m
2
.
Surface treatment
anti-glare and hard coating (>2H).
visual angle
±55° (horizontal), ±60° (vertical).
PYRANOMETER
probe measuring the insolation
Range 0 ÷ 2000W/m², accuracy ±2%
over any the whole measurement range according to the manufacturer's certification
Other characteristics according to the manufacturer's manual provided with the device
AMBIENT
TEMPERATURE
PT100 probe measuring the ambient temperature
Range -30 ÷ +80°C
Accuracy ± 1% ± 1°C from 0 to +80°C
TEMPERATURE OF
THE SOLAR
PANELS
PT100 probe measuring the temperature of the solar panels
Range -30 ÷ +120°C
Accuracy ± 1% ± 1°C from 0 to +90°C
CHECK THAT THE PANEL IS CLASS II
BEFORE PLACING THE TEMPERATURE PROBE
DC VOLTMETER
CAT IV 600 V
3 inputs for the simultaneous measurement of the output voltages of 3 solar panels
1000V
DC
full scale - accuracy ± 1% from 10 to 1000V
DC
3 inputs for the simultaneous measurement of the output current of 3 solar panels
PAC10-FTV clamp
200A
DC
full scale - accuracy ± 1% from 2 to 200A
DC
DC AMMETER
Use a CAT III 600 V
class II clamp
PAC20-FTV clamp
(with the dedicated instrument only)
1400A
DC
full scale - accuracy ±1% from 5
àto1400A
DC
AC VOLTMETER
CAT IV 600
3 inputs for the simultaneous measurement of the voltages of three-phase lines with or
without neutral (use input 1 for single-phase lines)
600V
AC
50Hz full scale - accuracy ±1% from 80 to 600V
AC
3 inputs for the simultaneous measurement of the currents of three-phase lines (use
input 1 for single-phase lines)
MN-FTV mini-clamp
200A
AC
full scale - accuracy ±1% from 2 to 200A
AC
C107-FTV clamp
(with the dedicated instrument only)
1000A
AC
full scale - accuracy ±1% from 5 to
1000A
AC
AC AMMETER
Use a CAT III 600 V
class II clamp
D43-FTV clamp
(with the dedicated instrument only)
3000A
AC
full scale - accuracy ±1% from 5 to
3000A
AC
AC/DC POWER
accuracy < 2%
CALCULATION
FUNCTIONS
efficiency of the photovoltaic panels
with compensation for the temperature coefficient of the modules
inverter conversion efficiency
DATA RECORDER
memory, including:
customer permanent data,
characteristics of the system, measurements and test results
Each of the 20 sites can acquire up to 12 measurement reports (certifications).
COMMUNICATION
PORT
RS232 + USB for management of the boards and transfer of the data to a PC
INTERNAL POWER
SUPPLY
Li-Ion battery pack, 4.5Ah, 8h life between charges
MAINS POWER SUPPLY
by external power supply unit 220V
AC
- 50Hz, 115VA, output 14.5-16V
DC
Содержание Green TEST-FTV 100
Страница 1: ... Testing instrument for photovoltaic installations ENGLISH User s manual ...
Страница 14: ...GREEN TEST FTV 100 English Page 14 sur 47 ...
Страница 15: ...GREEN TEST FTV 100 English Page 15 sur 47 ...
Страница 35: ...GREEN TEST FTV 100 English Page 35 sur 47 Example of a Report of on site measurement on the tests performed ...