CURRENT CLAMPS
Press ENTER to select the "CURRENT CLAMPS" MENU.
Move the cursor to the desired IDC clamp model and press ENTER to validate your choice (a red asterisk "*"
appears on the option chosen).
Move the cursor to the desired IAC clamp model and press ENTER to validate your choice.
(a red asterisk "*" appears on the option chosen).
8.5 CONFIGURATION
Press ENTER to display the data of the instrument for updates and periodic checks:
♦
Serial number;
♦
Microprogram version installed;
♦
Version of video board.
8.6 REMOTE MEASUREMENT
Press ENTER to select REMOTE MEASUREMENT.
Place the cursor on the desired option and press ENTER to select the type of measurement.
♦
LOCAL
Press ENTER to select use of the local atmospheric input values present in the instrument, without the help
of the remoted FTV 100 module
(a red asterisk "*" appears on the option chosen).
A test of communication with the remoted module is performed. An indication, OK or REJECTED, appears at
the end of not more than 30 seconds (...Loading, flashing).
On the main screen, the REMOTE MEASUREMENT indication changes to ON.
The following functions can be activated only with the remoted FTV 100 module on and connected by
the optional communication kit (cable or Bluetooth).
♦
REMOTE WITHOUT T pan
Press ENTER to select use of the local atmospheric input values present on the remoted FTV 100 module,
without the AMBIENT TEMPERATURE value
(a red asterisk "*" appears on the option chosen).
The texts OK or REJECTED that appear at the end of 30 seconds (...LOADING, flashing) indicate the result
of the link with the data of the remoted FTV 100 module, and are confirmed on the main screen, to the right
of REMOTE MEASUREMENT, by ON or REJECTED.
♦
REMOTE WITH T pan
Press ENTER to select the use of the local atmospheric input values present on the remoted FTV 100
module, with the AMBIENT TEMPERATURE value
(a red asterisk "*" appears on the option chosen).
The texts OK or REJECTED that appear at the end of 30 seconds (...LOADING, flashing) indicate the result
of the link with the data of the remoted FTV 100 module, and are confirmed on the main screen, to the right
of REMOTE MEASUREMENT, by ON or REJECTED.