GREEN TEST-FTV 100
English
Page 10 sur 47
When it exceeds the NOCT, the coefficient falls below 0.85 and
the panel loses efficiency (see page 34, §15.2).
The variation of the temperature coefficient also depends on the
values entered for Gamma and for NOCT.
REMARK: For all of the atmospheric measurements above, when the screen displays “---,--“ with the text
LOST (in red) at bottom right, communication has been broken off between the GREEN TEST instrument
and the remoted module. This interruption may be because the batteries of the remoted module are
discharged or because the signal has been lost (no Bluetooth link).
5.
THEORETICAL AVAILABLE POWER [kW]: theoretical power for an insolation of 1000 W/m²
(value entered by the user, see SITE MENU – NEW SITE DATA).
6.
DC MEASUREMENTS:
Display blank
V1: DC voltage or “- * -“
I1: direct current or -37.9A (-279.3A in 1.4kA version)
V2: DC voltage or “- * -“
I2: direct current or -38.1A (-279.8A in 1.4kA version)
V3: DC voltage or “- * -“
I3: direct current or -38.9A (-276.2A in 1.4kA version)
-
∗∗∗∗
-:
alert for each individual input (V1, V2, or V3):
No connection to the PV system
Voltage < 10V
DC
DC polarity reversed
AC voltage on DC inputs (connection error)
The “
- * -
” symbol also flashes
WARNING is displayed at bottom right of the screen
7.
DC POWER [kW]: indicates the measured direct current power from the solar generator.
8.
ALTERNATING CURRENT MEASUREMENTS:
Display blank
V1: AC voltage or “- * -“
I1: alternating current (2.0A for the 3kA version)
V2: AC voltage or “- * -“
I2: alternating current (1.0A for the 3kA version)
V3: AC voltage or “- * -“
I3: alternating current (1.1A for the 3kA version)
-
∗∗∗∗
-:
alert for each individual input (V1, V2, or V3):
No connection to the PV system
Voltage < 25V
AC
The “
- * -
” symbol also flashes
WARNING is displayed at bottom right of the screen
REMARK: when connecting to the PV system, check that the phases correspond (V1-I1, V2-I2, etc.)
9.
AC POWER [kW]: indicates the measured AC output power of the inverter.
10.
EFFICIENCY OF PANELS: indicates the efficiency of the photovoltaic generator as a
percentage (%), along with all of the test results.
REMARK: if Italian is the language selected for this device, under the provisions of standards applicable in
Italy (DM19/02/2007, IEC guide 82-25), the results of the "Good/Bad" tests appear alongside the %
efficiencies.