5 SWITCH
Switch with 24 positions to select the functions and ranges.
(See drawing in § 12 - APPENDIX)
2 ANALOGUE DISPLAY
The dial comprises 6 scales:
■
2 black scales, with antiparallax mirror,
for V DC and AC (0.100 and 0.30)
■
1 green scale for
Ω
(0.10k)
■
1 black scale for A DC (0.15)
■
1 red scale for A AC (0.15)
■
1 red scale for dB (0.22)
1 TERMINALS
∅
4 mm safety terminals
■
COM
: common, terminal that receives the black lead
■
V
Ω
Ω
Ω
Ω
Ω
: terminal that receives the red lead for voltages and resistances
■
15A
: terminal that receives the red lead for the 15A ranges
■
µµµµµ
mA
: terminal that receives the red lead for the
µ
A, mA
and 1.5 A ranges
2 - DESCRIPTION
3 “FUS” LIGHT
Neon for testing the 1.6 A and 16 A fuses on current measurement.
If the “Fus.” light comes on, change the faulty fuse(s).
NB: This light requires the presence of a voltage
≥
100 V to come on.
4 “VOLTEST” LIGHT
Voltage presence light on ohmmeter.
If the “Voltest” light comes on: presence of a voltage U > 15 V
AC/DC.Unplug the leads and cut off the voltage before making
the resistance measurement.