Operation
-12-
Colorado™ 4 IP User Manual Rev. 2
Dimmer Curves
This setting determines how fast the output of the COLORado™ 4 IP changes when you
modify the values of the Red, Green, Blue, White, and Dimmer faders. This setting
provides four different options to simulate the dimming speed of an incandescent lighting
product.
1. Go to the
SET
main level.
2. Select
DIMX
.
3. Select a dimmer curve (
OFF
,
DIM1
,
DIM2
,
DIM3
, or
DIM4
).
OFF:
The output is proportional (linear) to the Dimmer and RGBW channel
values.
DIM1~4:
The output follows the Dimmer and RGBW channel values based on the
corresponding dimmer speed, being
DIM1
the fastest and
DIM4
the
slowest.
Curve Settings
This setting determines the shape of the output curve of the COLORado™ 4 IP when
you modify the values of the Red, Green, Blue, White, and Dimmer faders. This setting
provides three different options to simulate the dimming curve of an incandescent
lighting product.
1. Go to the
SET
main level.
2. Select
CURV
.
3. Select a dimmer curve (
OFF
,
CV1
,
CV2
, or
CV3
).
OFF
This output is proportional (linear) to the Dimmer and RGBW channel
values.
CV1~3
This output follows the Dimmer and RGBW channel values based on the
corresponding dimmer curve, being
CV1
the fastest and
CV3
the slowest.
Control Panel Lock
This setting enables you to activate or disable the control panel lock, which keeps
unauthorized personnel from changing the product’s settings.
1. Go to the
SET
main level.
2. Select
KEY
3. Select
ON
or
OFF
.
When the control panel lock is active, the product will prompt you to enter the
password after 30 seconds of control panel inactivity or after turning on the
product.
Password
After being prompted to enter the password:
Press
<UP>, <DOWN>, <UP>, <DOWN>, <ENTER>
Settings Lock Out
This setting enables you to activate or disable the main level
SET
(settings) lock, which
keeps unauthorized personnel from changing the product’s settings.
1. Go to the
SET
main level.
2. Select
SLCK
.
3. Select
ON
or
OFF
.