52
Troubleshooting
Product Manual - Trifecta
®
XPro Series
Bulk Tank
Pressure
(Analog
Gauge)
__________
PSIG
Pressure (from PLC Display)
__________
PSIG
Tank 1
Pressure
(Analog
Gauge)
__________
PSIG
Pressure (from PLC Display)
__________
PSIG
Liquid Level (from PLC Display)
__________
“H
2
0
Liquid Level (from Analog Gauge)
__________
“H
2
O
Tank 2
Pressure
(Analog
Gauge)
__________
PSIG
Pressure (from PLC Display)
__________
PSIG
Liquid Level (from PLC Display)
__________
“H
2
0
Liquid Level (from Analog Gauge)
__________
“H
2
O
PLC Information
Press left arrow/record PB Set Point
__________
PSIG
Press up arrow/record Fill Set Point
__________
“H
2
0
Press down arrow/record bulk critical
__________
PSIG
Cycle Count (if equipped with counter)
__________
#cycles
Press”OK”/record Error Codes and elapsed time since event:
P _____ M _____ A _____ B _____
C _____ D _____ E _____ F _____
When __________ hr __________ minute
Note that the transmitter and gauge readings may not match exactly A discrepancy can be caused by either the analog gauge
or by the transmitter
In most cases, the result is an inaccurate analog gauge. Replace this gauge first.
Содержание Trifecta XPro Series
Страница 2: ......
Страница 24: ...20 Operation Product Manual Trifecta XPro Series Mode 0 Figure 1 Filling Mode Vent to Storage...
Страница 25: ...21 Operation Product Manual Trifecta XPro Series Mode 0 Figure 2 Filling Mode Vent to Atmosphere...
Страница 26: ...22 Operation Product Manual Trifecta XPro Series Mode 0 Figure 3 Filling Mode Liquid Flow...
Страница 27: ...23 Operation Product Manual Trifecta XPro Series Mode 0 Figure 4 Filling Mode Low Loss...
Страница 28: ...24 Operation Product Manual Trifecta XPro Series Mode 0 Figure 5 Filling Mode Low Loss Vent to Atmosphere...
Страница 29: ...25 Operation Product Manual Trifecta XPro Series Mode Switch 0 to 1 Figure 6 Fill Mode Termination...
Страница 31: ...27 Operation Product Manual Trifecta XPro Series Mode Switch 1 to 2 Figure 8 Secondary Maintains Hold Pressure...
Страница 32: ...28 Operation Product Manual Trifecta XPro Series Figure 9 Primary Pressure Build Mode 2...
Страница 33: ...29 Operation Product Manual Trifecta XPro Series Figure 10 Primary PB Off Mode 2...
Страница 34: ...30 Operation Product Manual Trifecta XPro Series Figure 11 Call for Assist Mode Switch 2 to 3...
Страница 35: ...31 Operation Product Manual Trifecta XPro Series Figure 12 Secondary Assist of Primary Assist Mode 3...
Страница 36: ...32 Operation Product Manual Trifecta XPro Series Mode Switch 3 to 2 Figure 13 Assist Complete Primary Restored...
Страница 40: ...36 Operation Product Manual Trifecta X Series...
Страница 43: ...39 Service Product Manual Trifecta XPro Series...
Страница 47: ...43 Service Product Manual Trifecta X Series...
Страница 48: ...44 Service Product Manual Trifecta X Series...
Страница 53: ...49 Preventive Maintenance Product Manual Trifecta XPro Series Front Isometric view of Trifecta 500 psig...