18
Operation
Product Manual - Trifecta
®
X-Series
HardSets
Thresholds
Factory
Default
Adjustable
Description
29.0"
Yes (up arrow)
default fill level
7.3"
Yes (function of fill level) primary to low to assist (.25 x fill level)
24.7"
Yes (function of fill level) secondary to low for assist mode (.85 x fill level)
550 psi
Yes (function of PB On) PBOff = PBOn +
25
psi
525 psi
Yes (left arrow)
default PBOn
425
psi
550 psi
No
PBOn upper limit is
450
psi
500 psi
Yes (function of PB On) Reserve tank PBOFF = Primary PBOn -
25
psi
475 psi
Yes (function of PB On) Reserve tank PBOn = Primary PBOn -
50
psi
475 psi
Yes (function of PB On) Primary pressure extreme low pressure threshold
150 psi
Yes (down arrow)
default Bulk Critical
150
psi
595 psi
No
Side #1 relief to bulk or atmosphere at
495 psi
595 psi
No
Side #2 relief to bulk or atmosphere at
495 psi
-5 psi
No
Transmitter Pressure to low (system will not operate)
650 psi
No
Transmitter Pressure to high (system will not operate)
3 seconds
No
Liq present at temp switch for
3
seconds
120 seconds
No
Temp switch will disarm for
120 seconds
after over pressure relief
10 seconds
No
If the pressure drops to the fast drop PB set within
10
seconds
535 psi
Yes (function of PB On) Fast drop on pb = PBOn +
10
psi
300 seconds
No
Fill time reaching
300
seconds results in the vent opening until full
140 psi
(100 psi bulk tank)
No
With bulk tank below critical pressure, the vent to atmosphere
valve will open at this set point = Bulkpsi(frozen) +
40
psi
55 psi
(100 psi bulk tank)
No
Low loss set point that turns of the vent to atmosphere
valve = Bulkpsi(frozen) -
45
psi (low loss)
70 psi
(100 psi bulk tank)
No
Low loss set point that turns of the vent to atmosphere
valve = Bulkpsi(frozen) - 45 psi (low loss)
27.5"
Yes (function of fill level)
Fill level is reduced by 1.5" to account for liquid growth for
cylinder pressures above 130 psi
130 psi
No
Pressure threshold that takes subtracts 1.5" from the fill level
80 to 130 psi
No
Nominal cylinder pressure. Fill levels at fill set point.
80 psi
No
Pressure threshold that takes adds 1.5" from the fill level
30.5"
Yes (function of fill level)
Fill level is increased by 1.5" to account for liquid growth
change for cylinder pressures below 80 psi
10 seconds
No
Primary pressure below PB On set for
10
seconds will result
in the secondary assisting the primary tank.
120 seconds
No
Primary pressures below the PB on threshold for
120
sec will
activate the light/display message, freeze the error codes and start
the low pressure timer.
360 seconds
No
Alert code A1 is activated
128+A5 seconds
No
Flow timer - limit to deliver 4" of product. Activates E5 error
25.0"
No
Start flow timer at this liquid level.
18.0"
No
Stop flow timer at this liquid level.
Hard Sets cont.
Hardsets (600 psig)
Содержание Trifecta XPro Series
Страница 2: ......
Страница 24: ...20 Operation Product Manual Trifecta XPro Series Mode 0 Figure 1 Filling Mode Vent to Storage...
Страница 25: ...21 Operation Product Manual Trifecta XPro Series Mode 0 Figure 2 Filling Mode Vent to Atmosphere...
Страница 26: ...22 Operation Product Manual Trifecta XPro Series Mode 0 Figure 3 Filling Mode Liquid Flow...
Страница 27: ...23 Operation Product Manual Trifecta XPro Series Mode 0 Figure 4 Filling Mode Low Loss...
Страница 28: ...24 Operation Product Manual Trifecta XPro Series Mode 0 Figure 5 Filling Mode Low Loss Vent to Atmosphere...
Страница 29: ...25 Operation Product Manual Trifecta XPro Series Mode Switch 0 to 1 Figure 6 Fill Mode Termination...
Страница 31: ...27 Operation Product Manual Trifecta XPro Series Mode Switch 1 to 2 Figure 8 Secondary Maintains Hold Pressure...
Страница 32: ...28 Operation Product Manual Trifecta XPro Series Figure 9 Primary Pressure Build Mode 2...
Страница 33: ...29 Operation Product Manual Trifecta XPro Series Figure 10 Primary PB Off Mode 2...
Страница 34: ...30 Operation Product Manual Trifecta XPro Series Figure 11 Call for Assist Mode Switch 2 to 3...
Страница 35: ...31 Operation Product Manual Trifecta XPro Series Figure 12 Secondary Assist of Primary Assist Mode 3...
Страница 36: ...32 Operation Product Manual Trifecta XPro Series Mode Switch 3 to 2 Figure 13 Assist Complete Primary Restored...
Страница 40: ...36 Operation Product Manual Trifecta X Series...