Code
Description
Action
C3
The temperature
switch has detected
liquid at the vent
muffler.
Reduce fill levels.
Check DP Transmitter.
Check thermocouple connection.
Check termperature switch
function.
D0
OK!
None
D4
Overpressure has
occurred. Tank or
Tanks have vent back
to storage.
Check fill levels.
Check PB valve function.
Check DP transmitter accuracy.
E0
OK!
None
E5
System has
exceeded the flow
rating.
Check for house line leaks.
Check for system leaks.
Need additional or next size
Trifecta XPro Series.
F0
OK!
None
F6
One of the systems
transmitters has gone
out of range
Check electrical connects.
Replace faulty transmitter.
The alert light will flash when the system has seen a low
pressure event A low pressure event is when both primary
and secondary tanks are below the PB On set point for 90
seconds During the alert status the system will continue to
attempt to recover In the service menu activated by pressing
the “OK” button a timer is displayed showing the running
time from the alert event (example: 3 hours and 24 minutes
since the low pressure event that activated the alert light) At
the moment of the alert the error codes are frozen to assist
in trouble shooting (alert codes during a non-alert events are
reset at every fill). Reset the frozen codes by pressing the
“OK” button and the “-” button simultaneously
Manually Operating the Valves
With the system in the “Monitor” mode, valves and valve
sets can be operated by pressing the “ESC” button and the
arrow buttons (see Button Press Summary for details)
The solenoids have a manual over-ride hand wheel
• Turning the red wheel in (clockwise) over-rides the
solenoid locking the valve open
• Turning the red wheel out (counter-clockwise) allows the
solenoid to open and close the valve electrically
Содержание Trifecta XPro Series
Страница 2: ......
Страница 24: ...20 Operation Product Manual Trifecta XPro Series Mode 0 Figure 1 Filling Mode Vent to Storage...
Страница 25: ...21 Operation Product Manual Trifecta XPro Series Mode 0 Figure 2 Filling Mode Vent to Atmosphere...
Страница 26: ...22 Operation Product Manual Trifecta XPro Series Mode 0 Figure 3 Filling Mode Liquid Flow...
Страница 27: ...23 Operation Product Manual Trifecta XPro Series Mode 0 Figure 4 Filling Mode Low Loss...
Страница 28: ...24 Operation Product Manual Trifecta XPro Series Mode 0 Figure 5 Filling Mode Low Loss Vent to Atmosphere...
Страница 29: ...25 Operation Product Manual Trifecta XPro Series Mode Switch 0 to 1 Figure 6 Fill Mode Termination...
Страница 31: ...27 Operation Product Manual Trifecta XPro Series Mode Switch 1 to 2 Figure 8 Secondary Maintains Hold Pressure...
Страница 32: ...28 Operation Product Manual Trifecta XPro Series Figure 9 Primary Pressure Build Mode 2...
Страница 33: ...29 Operation Product Manual Trifecta XPro Series Figure 10 Primary PB Off Mode 2...
Страница 34: ...30 Operation Product Manual Trifecta XPro Series Figure 11 Call for Assist Mode Switch 2 to 3...
Страница 35: ...31 Operation Product Manual Trifecta XPro Series Figure 12 Secondary Assist of Primary Assist Mode 3...
Страница 36: ...32 Operation Product Manual Trifecta XPro Series Mode Switch 3 to 2 Figure 13 Assist Complete Primary Restored...
Страница 40: ...36 Operation Product Manual Trifecta X Series...
Страница 43: ...39 Service Product Manual Trifecta XPro Series...
Страница 47: ...43 Service Product Manual Trifecta X Series...
Страница 48: ...44 Service Product Manual Trifecta X Series...
Страница 53: ...49 Preventive Maintenance Product Manual Trifecta XPro Series Front Isometric view of Trifecta 500 psig...