45
Service
Product Manual - Trifecta
®
Pro Series
Pressure and Liquid Level Transmitters
1
Leak check all fittings associated with the transmitter to verify the circuit has zero leaks. The sensor error check function
is designed to find problems such as a wire coming disconnected, or a short in the transmitter. See the Service section of
this manual for Alerts and Alarms
2
Confirm that all wiring connection terminals are tight.
3
If all connections are made and the Alarm condition does not go away, check the transmitter output.
4 Recalibrate or replace the transmitter as necessary
5
Also verify display readouts versus the analog gauges for both pressure and differential pressure.
Ball Valve Maintenance and Repair
Chart recommends that these ball valves have their stem seals checked and tightened at least every six months Ball seals and
actuator seals should also be checked and replaced at least once per year
Extended stem and short stem Worcester cryogenically-rated ball valves are used for isolation valves. These valves, for the
most part, stay in the open position. Chart recommends these ball valves have their stem seals checked and tightened at least
every six months Ball seals should also be checked at least once per year and replaced as required
Содержание Trifecta Pro Series
Страница 2: ......
Страница 20: ...16 Installation Product Manual Trifecta Pro Series...
Страница 28: ...24 Operation Product Manual Trifecta Pro Series Mode 0 Figure 1 Filling Mode Vent to Storage...
Страница 29: ...25 Operation Product Manual Trifecta Pro Series Mode 0 Figure 2 Filling Mode Vent to Atmosphere...
Страница 30: ...26 Operation Product Manual Trifecta Pro Series Mode 0 Figure 3 Filling Mode Liquid Flow...
Страница 31: ...27 Operation Product Manual Trifecta Pro Series Mode 0 Figure 4 Filling Mode Low Loss...
Страница 32: ...28 Operation Product Manual Trifecta Pro Series Mode 0 Figure 5 Filling Mode Low Loss Vent to Atmosphere...
Страница 33: ...29 Operation Product Manual Trifecta Pro Series Mode Switch 0 to 1 Figure 6 Fill Mode Termination...
Страница 35: ...31 Operation Product Manual Trifecta Pro Series Mode Switch 1 to 2 Figure 8 Secondary Maintains Hold Pressure...
Страница 36: ...32 Operation Product Manual Trifecta Pro Series Figure 9 Primary Pressure Build Mode 2...
Страница 37: ...33 Operation Product Manual Trifecta Pro Series Figure 10 Primary PB Off Mode 2...
Страница 38: ...34 Operation Product Manual Trifecta Pro Series Figure 11 Call for Assist Mode Switch 2 to 3...
Страница 39: ...35 Operation Product Manual Trifecta Pro Series Figure 12 Secondary Assist of Primary Assist Mode 3...
Страница 40: ...36 Operation Product Manual Trifecta Pro Series Mode Switch 3 to 2 Figure 13 Assist Complete Primary Restored...
Страница 44: ...40 Operation Product Manual Trifecta Pro Series...