19
Operation
Product Manual - Trifecta
®
Pro Series
ALERT Screen Cont.
Date & Time
field — Displays current date and time
Alert
Table
• Trigger Column – Displays label of Alert
• Qty – Displays number of times Alert has been triggered
since Time Last Reset
• Acc Time – Displays Accumulated time of Alert since
Time Last Reset
• Message – Description of Alert
Note:
Selected Alert is shown with a blue
background and white text
Time Last Reset
— Date and Time of last Reset Status
Silence Alarms
button — Stops strobe light on control panel
from flashing if currently flashing. Will also silence any alarms
running to the customer facility from customer alarm relay
Reset Status
— Resets Quantity count and Accumulation
Time of each Alert and Alarm trigger
Home
— Jumps to first Active Alert
End
— Jumps to last Active Alert
Page Up
— Moves up 1 page of Active Alerts
Page Down
— Moves down 1 page of Active Alerts
Move Up
— Scrolls up Active Alerts
Move Down
— Scrolls down Active Alerts
Alarm History
— Opens the ALARM & ALERT HISTORY
Screen
Close
— Returns to MAIN Screen
ALARM Screen
Displays the Active Alarms (Shutdown Alarms)
ALARM & ALERT HISTORY Screen
Displays the history of Alarms and Alerts
Note:
Alerts are shown with a yellow
background and black text. Alarms are
shown with a red background and white
text. Selected Alarm/Alert is shown with
a blue background and white text.
Ack Alarm
button — Acknowledges selected Alarm/Alert
Ack All
— Acknowledges all Alarms and Alerts
Clear All
— Clears all Alarms and Alerts from History
Sort Alarms — Sorts the history by time or by trigger
Active Alerts — Displays the ACTIVE ALERTS screen
Active Alarms — Displays the ACTIVE ALARMS screen
RESET COUNTS Popup
Current Cycle Time
field — Amount of time for the current
cycle
Prev . Cycle Time
— Amount of time for previous cycle
Cycle Count
— Number of cycles Trifecta has had since last
reset
Reset
— Resets cycle count to 0 A non-resettable counter
can be found on a password protected screen
Содержание Trifecta Pro Series
Страница 2: ......
Страница 20: ...16 Installation Product Manual Trifecta Pro Series...
Страница 28: ...24 Operation Product Manual Trifecta Pro Series Mode 0 Figure 1 Filling Mode Vent to Storage...
Страница 29: ...25 Operation Product Manual Trifecta Pro Series Mode 0 Figure 2 Filling Mode Vent to Atmosphere...
Страница 30: ...26 Operation Product Manual Trifecta Pro Series Mode 0 Figure 3 Filling Mode Liquid Flow...
Страница 31: ...27 Operation Product Manual Trifecta Pro Series Mode 0 Figure 4 Filling Mode Low Loss...
Страница 32: ...28 Operation Product Manual Trifecta Pro Series Mode 0 Figure 5 Filling Mode Low Loss Vent to Atmosphere...
Страница 33: ...29 Operation Product Manual Trifecta Pro Series Mode Switch 0 to 1 Figure 6 Fill Mode Termination...
Страница 35: ...31 Operation Product Manual Trifecta Pro Series Mode Switch 1 to 2 Figure 8 Secondary Maintains Hold Pressure...
Страница 36: ...32 Operation Product Manual Trifecta Pro Series Figure 9 Primary Pressure Build Mode 2...
Страница 37: ...33 Operation Product Manual Trifecta Pro Series Figure 10 Primary PB Off Mode 2...
Страница 38: ...34 Operation Product Manual Trifecta Pro Series Figure 11 Call for Assist Mode Switch 2 to 3...
Страница 39: ...35 Operation Product Manual Trifecta Pro Series Figure 12 Secondary Assist of Primary Assist Mode 3...
Страница 40: ...36 Operation Product Manual Trifecta Pro Series Mode Switch 3 to 2 Figure 13 Assist Complete Primary Restored...
Страница 44: ...40 Operation Product Manual Trifecta Pro Series...