Appendix 1
Product Manual - Liquid Cylinders
Visual
Dents greater
than ½” deep &
6” in length
Bench test
and/or replace
faulty gauge
Remove
regulator, bench
test and set to
recommended
point
Replace defective foot
ring, shock mount,
caster, bolts or nuts as
recommended
Send cylinder
to repair
facility
Check free
flowing gas from
GU & PB
Pass
Pass
Fail
Fail
Fail
No
Positive
pressure
Regulator
(s)
PSI
Gauge
L L
Gauge
Vertical
stance
Correct gas
product and
grade
With positive
pressure in
cylinder test
valve seats,
repair or rebuild
as required
Depressurize
cylinder, remove
gauge; set zero
point, replace or
upgrade
Sample residual
gas and purge
cylinder with
designated gas
product to insure
proper purity
Weigh cylinder;
remove residual
liquid and
sample gas
Reading
Zero
Correct
gas
No
Pass
Operation
Valves
Check condition
of gas service
fittings and
tamper devices,
replace fittings
as required
Test valves for
smooth
operation, repair
as required
Repair or replace
devices as
necessary
Repair fittings if
able
Permanent
fitting
valves
Fail
Fail
Fail
Pass
Relief
Valve
Inspect pressure
set points
compared to
DOT plate
Inspect for
damage or wear
Missing DOT
Plate
–
DO
NOT FILL
CYLINDER!
Notify
manufacturer
for
disposition
Bench test,
replace valve if
necessary
Pressure
burst disc
Inspect pressure
set points
compared to
DOT plate
Inspect for
damage or wear,
replace if
necessary
Pass
Pass
Inspect pressure
set points
compared to
DOT plate. Make
adjustments as
required
Check gas
service of liquid
level gauge or
gauge label;
change if needed
Rebuild or
replace
regulator,
upgrade to
combination
regulator
Check liquid
level protector
color-coding
compared to
cylinder pressure
rating, replace if
needed
Inspect for
tampering
damage or wear.
Make
adjustments as
required
Pass
Labeling
Check gas
service label,
pressure
rate
compared to
DOT plate,
replace if needed
Pass
Fill
Cylinder
Connect transfer
line(s) and record
tare weight
Determine and
record the total fill
weight adding tare
weight to
manufactures DOT
fill weight.
Place cylinder on
scale; compare
empty (tare) weight
of cylinder to tare
weight on DOT
plate - any overage
is residual gas
Sample residual
gas in cylinder;
purge the cylinder if
necessary
Open cylinder vent
and liquid valves;
open the shut off
valve of transfer
line allowing liquid
to flow. When
scale reads the
total fill weight
close the cylinder
fill valve; close
cylinder vent valve.
Close transfer line
shut off valve and
loosen to relieve
any pressure from
line. Remove
transfer line from
cylinder and
cylinder from scale
Rapid
Pressure
Rise
Move cylinder to
scale. Determine
the correct total fill
weight. Compare
and remove any
excess gas product
Check condition of
cylinder relief
devices;
depressurize and
replace as needed
May indicate poor
vacuum insulation;
perform NER test
Cylinder is
over filled
Liquid level
may be above
the internal
vent line
Total weight
may be
exceed DOT
fill weight
Pass
Pressure rise should not
exceed 50 psi per day
Fail
See
Excess
Pressure
Vacuum
condition
Check condition
of vacuum
rupture disc?
Warranty seal
present?
Protective cover
present?
Check condition
of manufactures
evacuation
valve, relief
device
AND / OR
Fail
Fail
Troubleshooting Flow Chart #1
Содержание Cryo-Cyl80HP
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 32: ......
Страница 50: ...44 Specifications Product Manual Liquid Cylinders MCR Plumbing Configuration...
Страница 52: ...46 Specifications Product Manual Liquid Cylinders LCCM Plumbing Configuration...
Страница 54: ......
Страница 56: ......
Страница 57: ...51 Product Manual Liquid Cylinders Appendix 1 Troubleshooting Guides Cutaway Explanation...
Страница 62: ...56 Appendix 1 Product Manual Liquid Cylinders Troubleshooting Flow Chart 3...