33
Maintenance
Product Manual - Liquid Cylinders
6
Referring to Figure 19 for the proper torque sequence,
torque each screw to 50 in/lbs
7
Using the same sequence, torque each screw to 70 in/
lbs
Figure 19
Portable Regulator Bench Setting
Use the following procedure to change the pressure range for
either the pressure building or economizer regulator.
1
Remove the liquid product from the liquid cylinder.
Vent the liquid cylinder of all pressure.
2
Remove the regulator from the liquid cylinder
3
Place the regulator body in a vise with the bonnet and
adjusting screw pointed up.
4
Back out the adjusting screw until there is no spring
pressure on it.
5
Remove the regulator dome from the body
6
Carefully remove only the spring.
7
Replace the spring and reassemble.
8
See table below for appropriate springs.
Alternate Regulator Springs
Pressure Builder
Economizer
Pressure
(PSI)
Part No.
Pressure
(PSI)
Part No.
2 - 25
5710031
0 - 3-
5710241
15 - 65
5710191
30 - 50
5710211
40 - 100
5710111
51 - 80
5710151
100 - 250
5710201
81 - 150
5710161
151 - 250
5710341
200 - 400
5710301
Bench Setting an MCR Regulator
1
Connect the pressure control regulator to a nitrogen
pressure source as shown in Figure 20.
2
Connect “EC OUT” (economizer out) port to tee on
“PB OUT” of regulator with a piece of tubing.
3
Close valve “B”. Open valve “D”.
4
Open the pressure source valve (follow appropriate
safety rules).
5
Open valve “C” slowly.
6
Pressure gauge “A” will indicate the pressure to which
the regulator has been set. The pressure can be increased
by turning the adjusting screw in. The pressure may be
decreased by turning the screw out; however, after each
adjustment outward it will be necessary to open and
then close valve “B” to relieve excess pressure.
7
This setting should match the calibrated scale If it does
not, go to step 8.
8
Loosen lock nut “E” and adjust screw “F” until
calibrated scale matches set pressure. When completed,
tighten lock nut “E”. “E” and “F” are only to be
loosened or adjusted during bench setting procedure.
Factory Settings:
MP
125 psig
HP
300 psig
Figure 20
Small Diameter Tube
Large
Diameter
Tubes
Torque
Sequence
Содержание Cryo-Cyl80HP
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 32: ......
Страница 50: ...44 Specifications Product Manual Liquid Cylinders MCR Plumbing Configuration...