34
Maintenance
Product Manual - Liquid Cylinders
Bench Setting a PB Regulator
1
Connect the pressure building regulator to a nitrogen
pressure source as shown in Figure 21.
2
Close valve “B” and “D”.
3
Open the pressure source valve (follow the appropriate
safety rules).
4
Open valve “C” slowly.
5
Pressure gauge “A” will indicate the pressure to which
the regulator has been set. The pressure can be increased
by turning the adjusting screw in. The pressure may be
decreased by turning the screw out; however, after each
adjustment outward it will be necessary to open and
then close valve “B” to relieve excess pressure.
Figure 21
Bench Setting an Economizer Regulator
1
Connect the inlet of the economizer regulator to a
pressure source as shown in Figure 22.
2
Open the valve at the pressure source (follow
appropriate safety rules).
3
Slowly open valve “B”.
4
Pressure gauge “A” will indicate the setting to which
the economizer regulator is set This setting may be
increased by turning the adjusting screw in, or lowered
by turning the adjust screw out
5
Gas will flow through the economizer regulator when
the pressure of the gas reaches the preset setting.
Figure 22
Содержание Cryo-Cyl80HP
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 32: ......
Страница 50: ...44 Specifications Product Manual Liquid Cylinders MCR Plumbing Configuration...
Страница 52: ...46 Specifications Product Manual Liquid Cylinders LCCM Plumbing Configuration...
Страница 54: ......
Страница 56: ......
Страница 57: ...51 Product Manual Liquid Cylinders Appendix 1 Troubleshooting Guides Cutaway Explanation...
Страница 62: ...56 Appendix 1 Product Manual Liquid Cylinders Troubleshooting Flow Chart 3...