6
LT7272 (ISS 1)
The Paragon P3 incorporates a single gas control, which selects ignition pilot, and main burner low and high settings.
The Paragon P3 incorporates a safety device in the form of an Oxygen Depletion System, which constantly monitors
the oxygen in the room and will cause the fire to switch off if the oxygen level reduces, for instance due to insufficient
ventilation or a blocked flue.
If this repeatedly occurs do not attempt to relight the appliance until a qualified engineer has checked it, the problem
may not be due to lack of air or a defective flue.
Warning:- This appliance has a naked flame, has with all such fires it is essential that a fireguard should be used for
the protection of children, the elderly and infirm. Fireguards should conform to BS 6539 (1984) (Fireguards for use
with solid fuel appliances).
During the normal operation of the fire some black staining or soot may appear on some parts of the fuel bed. This is
quite normal and adds to the appearance of the appliance. However, if excessive black staining does occur it may be
due to the fuel bed being incorrectly laid. This should be checked prior to contacting a service engineer.
SECTION TWO Operation (user instructions)
The pilot can be left on or the pilot can be extinguished and relit each time the fire is used.
The appliance Control Knob is positioned behind the fret.
The full lighting procedure is as follows: -
A.
Push knob in as far as possible on gas control.
B.
Turn knob anti-clockwise until a click is heard. The knob will stop at the position marked
'
'
and a spark
should be seen at the tip of the ignition probe. At the same time the pilot flame should light. KEEP THE
KNOB PRESSED IN FOR 20 SECONDS. Should the pilot fail to light, turn the control knob clockwise to the
'
'
position, wait 3 minutes and repeat the procedure.
C.
After lighting the pilot flame the control knob should be allowed to spring out slightly. This will allow you to
turn the knob further anti-clockwise to the position marked
'
'
. The pilot flame should then ignite the main
fire.
D.
It is possible to adjust the height of the flames by turning the control knob between the positions marked
'
'
and
'
'
. Note that the knob 'latches' in position at either end of this movement and must be pushed in
slightly before it can be turned.
E.
To turn the fire off, depress the knob slightly and turn it to the
'
'
position.
F.
To completely extinguish the fire, depress the knob slightly and turn to
'
'
the position.
Note: - If the ignition fails the pilot can be lit with a taper or a match held at the pilot head.
Содержание Paragon P3
Страница 8: ...8 LT7272 ISS 1 ...
Страница 9: ...www charltonandjenrick co uk 9 LT7272 ISS 1 ...
Страница 10: ...10 LT7272 ISS 1 ...
Страница 19: ...www charltonandjenrick co uk 19 LT7272 ISS 1 Insert the flue adaptor within the roof of the firebox as shown ...
Страница 24: ...24 LT7272 ISS 1 ...
Страница 25: ...www charltonandjenrick co uk 25 LT7272 ISS 1 Register your appliance online today to active your warranty ...