The Paragon P3 incorporates a single gas control, which selects ignition pilot, and main burner low and high settings.  

 

The Paragon P3 incorporates a safety device in the form of an Oxygen Depletion System, which constantly monitors 
the oxygen in the room and will cause the fire to switch off if the oxygen level reduces, for instance due to insufficient 
ventilation or a blocked flue. 

If this repeatedly occurs do not attempt to relight the appliance until a qualified engineer has checked it, the problem 
may not be due to lack of air or a defective flue. 

 

Warning:- This appliance has a naked flame, has with all such fires it is essential that a fireguard should be used for 
the protection of children, the elderly and infirm.  Fireguards should conform to BS 6539 (1984) (Fireguards for use 
with solid fuel appliances).   

 

During the normal operation of the fire some black staining or soot may appear on some parts of the fuel bed. This is 
quite normal and adds to the appearance of the appliance. However, if excessive black staining does occur it may be 
due to the fuel bed being incorrectly laid. This should be checked prior to contacting a service engineer. 

 

SECTION TWO Operation (user instructions) 

 

The pilot can be left on or the pilot can be extinguished and relit each time the fire is used. 

The appliance Control Knob is positioned behind the fret.   

 

The full lighting procedure is as follows: - 

A.

 

Push knob in as far as possible on gas control. 

B.

 

Turn knob anti-clockwise until a click is heard.  The knob will stop at the position marked 

'

'

 and a spark 

should be seen at the tip of the ignition probe.  At the same time the pilot flame should light.  KEEP THE 

KNOB PRESSED IN FOR 20 SECONDS.  Should the pilot fail to light, turn the control knob clockwise to the 

'

'

 

position, wait 3 minutes and repeat the procedure. 

C.

 

After lighting the pilot flame the control knob should be allowed to spring out slightly.  This will allow you to 

turn the knob further anti-clockwise to the position marked 

'

'

. The pilot flame should then ignite the main 

fire. 

D.

 

It is possible to adjust the height of the flames by turning the control knob between the positions marked 

'

'

 

and 

'

'

.  Note that the knob 'latches' in position at either end of this movement and must be pushed in 

slightly before it can be turned.  

E.

 

To turn the fire off, depress the knob slightly and turn it to the 

 '

'

 position. 

F.

 

To completely extinguish the fire, depress the knob slightly and turn to 

'

'

 the position. 

 

Note: -  If the ignition fails the pilot can be lit with a taper or a match held at the pilot head. 

Содержание Paragon P3

Страница 1: ...gandfuturereference For use in Great Britain and Ireland Literature NO 7272 ISS 1 IMPORTANT This appliance is guaranteed for 12 months subject to conditions The 5 year extended parts warranty will only be valid if the annual service recommended in this manual has been completed and appliance has been registered online ...

Страница 2: ...ller has filled in the appropriate checklist This in no way reduces your statutory rights Your warranty commences from the date of purchase and you must retain your receipt or invoice as proof of a purchase date THIS EXTENDED WARRANTY SPECIFICALLY EXCLUDES GLASS AND SOFT REFRACTORY COMPONENTS THE BULB AND ANY BATTERIES Terms and Conditions 1 The appliance must be installed by a GAS SAFE registered...

Страница 3: ...lations England and Wales All installations must be notified to Local Area Building Control either directly or through a Competent Persons Scheme A Building Regulations Compliance Certificate will then be issued to the customer who should on receipt write the Notification Number on the Benchmark Checklist This product should be serviced regularly to optimise its safety efficiency and performance T...

Страница 4: ... suggest you record the following details here and keep the receipt as proof of purchase This information may be asked for when you contact the helpdesk MODEL Paragon P3 Serial No This information can be found on the label attached to the packaging and on the data badge which is located on the top flange of the appliance Retailer Name Address Date Of Purchase ...

Страница 5: ...kin eyes nose and throat When handling avoid inhaling and contact with skin or eyes Use disposable gloves facemasks and eye protection After handling wash hands and other exposed parts If a vacuum is used for cleaning the fuel bed or cleaning after servicing installation it is recommended that it be of the type fitted with a HEPA filter Disposal of refractory ceramic materials To keep dust to a mi...

Страница 6: ...ECTION TWO Operation user instructions The pilot can be left on or the pilot can be extinguished and relit each time the fire is used The appliance Control Knob is positioned behind the fret The full lighting procedure is as follows A Push knob in as far as possible on gas control B Turn knob anti clockwise until a click is heard The knob will stop at the position marked and a spark should be seen...

Страница 7: ...icate and they should be handled with great care The loose parts may be removed for cleaning They can be brushed very gently with a soft brush to remove dust or any deposits A vacuum cleaner may only be used after the loose components and moulded shapes have been removed CARE SHOULD BE TAKEN TO AVOID CONTACT WITH THE REFRACTORY LINING THIS IS A DELICATE SURFACE AND SHOULD NOT BE WIPED OR RUBBED Th...

Страница 8: ...8 LT7272 ISS 1 ...

Страница 9: ...www charltonandjenrick co uk 9 LT7272 ISS 1 ...

Страница 10: ...10 LT7272 ISS 1 ...

Страница 11: ... Installer in accordance with the current Gas Safety Installation and Use Regulations 1998 as amended The chimney or flue should be checked annually to ensure clearance of combustion products Ventilation in the Great Britain GB Great Britain This fire does not normally require purpose build ventilation in accordance with 2010 document J Building Regulations Ventilation in the Republic of Ireland M...

Страница 12: ...mm2 2 12 sq ins SECTION FIVE Specification installation instructions NATURAL GAS Category of Appliance BAS Category I2H Gas type G20 Gas Pressure 20 mbar Gas input high 7 7 kW Gross Gas input low 4 0 kW Gross Injector Main Size 580 Oxy pilot 2550 NG Data Label Location On top flange of firebox Gas Connection 8 mm OD Tube NOTE The efficiency of this appliance has been measured as specified in BS797...

Страница 13: ...ndards BS 5871 BS 8303 BS 5440 part 1 BS 1251 BS 6891 BS 6461 parts 1 2 BS 715 BS 1289 part 1 2 Note This appliance must be installed to current versions of the above standards and include any relevant amendments The Building Regulations issued by the Department of the Environment The Building Standards Scotland Consolidation Regulations issued by the Scottish Development Office SECTION SEVEN Siti...

Страница 14: ...y impede the natural draught If a terminal is fitted it must be suitable for the purpose SECTION EIGHT Fireplace Requirements installation instructions A flat face of 600 mm high x 500 mm wide must be provided around the fireplace opening for the fixing of the appliance to ensure that a good seal is formed The base of the fire opening must be flat to ensure sound fixing of the appliance A non comb...

Страница 15: ...Consideration should be given to the location of the appliance ensuring it is very visible and it should be positioned at a height were it can clearly be seen on approach Frets and Fascias used for HOLE in the WALL must be compliant with Paragon Fires CE approval these are listed at the end of this page Where the fire is fitted as a Hole in the Wall without a hearth the installer MUST ensure the a...

Страница 16: ...o close to the appliance VENTILATION GB Great Britain This fire does not normally require purpose build ventilation in accordance with 2010 document J Building Regulations In the Republic of Ireland permanent ventilation must comply with the rules in force SECTION NINE To Install the Appliance installation instructions EXAMINE FLUE CHIMNEY Check that the flue chimney conforms to the required speci...

Страница 17: ... FROM THE FRONT Connections may be made from the front of the appliance from either the left or right in 8 mm diameter pipe If a left hand connection is required the tube should be routed behind the bezel plate under the gas control tap and onto the inlet elbow The inlet elbow can be rotated to the required position A suitable isolating cock must always be fitted in the supply feed to the fire to ...

Страница 18: ...ely the 4 eye bolts provided with suitable wall plugs Fix the fire casing back into the opening using the cable fixing system as shown in do not cut off loose ends of cable after fixing coil and tuck carefully behind burner tray Note when using the cable fixing kit with the spacer fix and seal the spacer to the rear of the appliance flange with the screws and foam seal provided 260mmCRS 30mm 460mm...

Страница 19: ...www charltonandjenrick co uk 19 LT7272 ISS 1 Insert the flue adaptor within the roof of the firebox as shown ...

Страница 20: ... ISS 1 Locate the canopy fixing cover over the three M4 studs position within the front edge of the flue adaptor Push the rear face of the bracket hard against the glass canopy and fix using the M4 Nuts provided ...

Страница 21: ...r for Natural Gas G20 CHECKING PRODUCT CLEARANCE Check for satisfactory clearance of combustion products Close all doors and windows and leave fire burning for 5 minutes Then position a smoke match just into the top of the fire opening at the bottom of the glass canopy and move it left and right all the smoke must be drawn into the flue If spillage occurs allow a further 5 minutes Should spillage ...

Страница 22: ...eration of the appliance Before commencing any service or replacement of parts turn off the gas supply to the fire After servicing check for gas soundness When ordering spare parts please quote appliance name and serial number these can be found on the data badge which is located by removing the decorative trim and fret At least once a year check for debris in the catchment area behind the fire an...

Страница 23: ... burner in the top of the main coal support and remove burner and silencer 3 Clean service or replace as necessary 4 Re assemble in reverse order For pebble bed push burner to right side when tightening securing screws 5 Turn on gas supply check for gas soundness and re commission appliance REPLACEMENT OF INJECTOR 1 Repeat operations 1 2 for removal of burner and or silencer 2 Disconnect gas conne...

Страница 24: ...24 LT7272 ISS 1 ...

Страница 25: ...www charltonandjenrick co uk 25 LT7272 ISS 1 Register your appliance online today to active your warranty ...

Страница 26: ...facturer s instructions Hearth Requirements where fitted Is the hearth constructed from non combustible material Is the hearth a minimum of 12mm thick with a minimum floor to top surface of 50mm BS5871 or as per manufacturer s instructions Is the hearth for open fronted fires a minimum of 760mm wide and has 300mm projecting from the fire opening BS6871 or to manufacturer s instructions Mounting he...

Страница 27: ...ays use the manufacturer s specified spare part when replacing controls SERVICE 01 Date Engineer name Company name Telephone No Gas safe register No Comments Signature SERVICE 02 Date Engineer name Company name Telephone No Gas safe register No Comments Signature SERVICE 03 Date Engineer name Company name Telephone No Gas safe register No Comments Signature SERVICE 04 Date Engineer name Company na...

Страница 28: ...Data Badge Fire Box Grommet Burner Tray Box Assembly Warning Label Fire Guard Fuel Bed Flue Adapter 7242 Glass Canopy Canopy Fixing Bracket 7243 Fixing 0705 includes 4 magnets foam seal Control Cover Plate 7247 plus 2 fixing screws Owners Book ID Label Packing Labels Serial Number Inspector ...

Отзывы: